Related Experiment Video
Updated: Jan 23, 2026

Adapted Resistance Training Improves Strength in Eight Weeks in Individuals with Multiple Sclerosis
Published on: January 29, 2016
Investigation of isometric strength and control of the upper extremities in multiple sclerosis
Asif Hussain1,2, Sivakumar Balasubramanian1,3, Ilse Lamers4
1Department of Bioengineering, Imperial College of Science, Technology and Medicine, UK.
Abstract:
Isometric force assessment can provide insights into strength and motor control in patients with neurological disabilities. This study investigated the connection between isometric strength and control in nine multiple sclerosis (MS) patients and four healthy subjects using a compact isometric setup. The participants carried out isometric assessment tasks in both upper extremities in six directions. Strength was measured through maximum voluntary force/torque (MVF/T), while control ability was measured by applying a constant force/torque of 25% of MVF/T. Isometric control was quantified using coefficient of variation, force directing ability, sample-entropy and spectral bandwidth. The MS patients were also assessed using two impairment measures (Motricity Index and hand-grip strength), and two activity measures (Action Research Arm Test and Nine Hole Peg Test). The results indicate that isometric strength and control (measured by spectral bandwidth) were correlated in most directions. Among the four control measures, spectral bandwidth - a measure introduced in this study - was found to be strongly related to the force/torque regularity as measured by sample-entropy. Isometric strength and spectral bandwidth for all directions were well correlated with the impairment measures, but their correlation with the activity scales was moderate and direction-dependent. Overall the results show potential for using the isometric setup and protocol for assessment in MS population.
Related Concept Videos
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...
Isotonic and Isometric Muscle Contractions
Isotonic contractions
Isotonic contractions occur when a muscle changes length while...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Relation Between Tensile Strength and Compressive Strength of Concrete
The Equilibrium Binding Constant and Binding Strength
Absolute and Local Extreme Values

