Related Experiment Video
Updated: Jan 23, 2026

Design of a Biocompatible Drug-Eluting Tracheal Stent in Mice with Laryngotracheal Stenosis
Published on: January 21, 2020
Comparison between the Outcomes of Using Biodegradable-Polymer Drug-Eluting Stents and Those of Using Durable-Polymer
Abd-Allah Y Fawzy1, Mahmoud M Kenawi1, Ahmed Abd El Aziz1
1Critical Care Medicine Department, Cairo University, Cairo, Egypt.
Background:
Many randomised control studies showed that percutaneous coronary interventions using biodegradable-polymer drug-eluting stents (DES) offer a safe and effective alternative to durable-polymer DES. However, not many studies have discussed its use in the setting of acute coronary syndromes.
Aim:
We aim to compare the biodegradable-polymer DES with durable-polymer DES when it comes to reducing the incidence of non-ST elevation acute coronary syndrome (NSTEACS) associated with adverse events.
Methods:
We enrolled 205 patients presenting with NSTEACS and a TIMI risk score ≥ 3 in this study and divided them into two groups, group A and group B. Biodegradable-polymer DESs were exclusively used in group A, while durable-polymer DESs were used in group B. Major adverse events were reported in both groups during the hospital stay and patients were followed-up for 1 year.
Results:
In our patients, we intervened on 390 diseased segments in a total of 360 vessels. After intervention, TIMI 0 was achieved in 0.97%, TIMI 1 in 1.46%, TIMI 2 in 2.45%, and TIMI 3 in 95.12% of the treated segments (P-value= 0.677). We implanted 121 biodegradable-polymer DESs and 146 durable-polymer DESs. Clinical success was achieved in 95.12% of our cases. We had 55 patients who needed repeated coronary angiography within 1 year (15 patients treated with biodegradable-polymer DES and 24 patients treated with durable-polymer DES). Eighteen patients experienced angina pains (8 patients treated with biodegradable-polymer DES and 10 patients treated with durable-polymer DES). Only 5 patients needed TLR (2 patients treated with biodegradable-polymer DES and 3 patients treated with durable -polymer DES) (P-value = 0.591), three of them had a myocardial infarction with documented angiographic evidence of significant in-stent restenosis (1 patient treated with biodegradable-polymer DES and 2 patients treated with durable-polymer DESs).
Conclusion:
Biodegradable-polymer DES represents a comparable alternative to durable-polymer DES in the setting of acute coronary syndromes.
More Related Videos
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
05:04Implantation of Human-Sized Coronary Stents into Rat Abdominal Aorta Using a Trans-Femoral Access
Published on: November 19, 2020
Related Concept Videos
Acute Coronary Syndrome I: Introduction
Acute Coronary Syndrome V: Nursing Management
Acute Coronary Syndrome II: Pathophysiology and Clinical Manifestations
Acute Coronary Syndrome III: Diagnostic Studies
Acute Coronary Syndrome IV: Interprofessional Care
Polymers