Related Experiment Video
Updated: Jan 23, 2026

Exploring the Radical Nature of a Carbon Surface by Electron Paramagnetic Resonance and a Calibrated Gas Flow
Published on: April 24, 2014
Exploration of the problems and solutions related to reference introduction prior to calibration of thermal
Adissu Alemayehu Asfaw1,2, Matthias Van der Veken1, Kris Wolfs1
1Department of Pharmaceutical and Pharmacological Sciences, Pharmaceutical Analysis, KU Leuven - University of Leuven, Leuven, Belgium.
Abstract:
Reference introduction in thermal desorption with gas chromatography is a critical aspect. It is mostly performed by offline liquid calibration using a micro syringe to inject a liquid standard solution on the sorbent in the thermal desorption tube. This is based on the assumptions that the adsorption-desorption process is quantitative and that no sample is lost in manipulating the tube. However, for analytical procedures involving thermal extraction of solid matrices, the adsorption-desorption processes for sample and reference differ and the assumptions are not always fulfilled. This is explored in this work. First, issues related to the online liquid calibration were investigated. With tubes containing only quartz filters, a relative loss of over 80% was noticed for some solvents due to tube manipulation processes. Enclosing a bed of mesoporous silica as sorbent limited the losses to about 25% when samples were immediately analysed, and even better results were obtained when tubes were stored for several hours so that proper adsorption could take place. An additional sweep gas during loading boosted the transfer of analytes with recoveries above 95%. Next, an inline injection system was installed on the thermal desorber instrument. This sorbent free, independent calibration tool avoids the drawbacks of other approaches.
More Related Videos
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...

