Efficiency comparison of the imidazole plus RNO method for singlet oxygen detection in biorelevant solvents
Johanna Herman1, Sharon L Neal2
1Department of Chemistry and Biochemistry, University of Delaware, Newark, DE, 19711, USA.
Abstract:
Singlet oxygen (1O2) is the focus of study in many fields, including phototoxicity, antioxidant activity, pollutant weathering, photodynamic therapy, and water disinfection. The imidazole plus RNO (Imd/RNO) method, originated by Kraljic and El Mohsni, is commonly used to monitor singlet oxygen production. In this method, 1O2 is quenched by an acceptor, imidazole (Imd), during the formation of a trans-annular peroxide intermediate that bleaches the sensor, p-nitrosodimethylaniline (RNO). Though the method has been widely used, including to monitor 1O2 production in complex environments, such as surfactants and cells, studies reporting the efficiency of the assay in complex solvents have not been reported. In this research, the Imd/RNO method in complex, biorelevant solvents, i.e., sodium dodecyl sulfate, octanol, and phosphate buffer-saturated octanol, was compared with reference solvents, i.e., phosphate buffer, ethanol, and methanol, for monitoring 1O2 produced by Rose Bengal photosensitization using time-resolved, broadband UV-Vis absorbance measurements. Rates of sensor bleaching and sensitizer photodegradation were simultaneously monitored in each solvent to investigate correlations between the disappearance rates of sensor and sensitizer. The quantum yields of 1O2 production (ϕ∆) in each solvent were calculated using a relative actinometric method. The dependence of sensor bleaching and sensitizer degradation on acceptor concentration and solvent polarity, and the results of assay controls suggest mechanistic differences underlying the reactions comprising the Imd/RNO method. These results demonstrate the need for caution and controls when using the method in complex samples including those containing cells, tissues, or nanoscale particles.
More Related Videos
Related Concept Videos
Solvents
A...
Titration in Nonaqueous Solvents
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...