Induction distribution of five-phase induction machines under open-phase fault
Luís Alberto Pereira1, Guilherme Nicol1, Luís Fernando Alves Pereira1
1Universidade Federal do Rio Grande do Sul - PPGEE, Av. Osvaldo Aranha, 103, Porto Alegre - RS, CEP: 90035-190, Brazil.
Abstract:
The main objective of the paper is to determine the induction distribution of five-phase induction machines operating under unbalanced steady state, focusing on the operation with two opened stator phases. Firstly, we present an analytical model based on symmetric components which includes the third harmonic component of the airgap induction. The model is then used to determine the induction distribution in the airgap and also in the main iron parts, i.e. cores and teeth of the stator and rotor parts. The analytical model is thoroughly validated through two-dimensional Finite Element Analysis (FEA) and using extensive experimental data obtained from tests taken on a prototype machine of 5.5 kW; experimental data, as well results from FEA, showed a close agreement with theoretical data, which confirms the accuracy of the proposed model. The results indicate that when two phases are opened and with no control strategy to compensate the fault, the induction distributions can change significantly, predominantly in the stator and rotor teeth, as a result of additional induction harmonic components. These changes in the field distribution of stator and rotor teeth, in turn, can increase the associated magnetic losses as they are no longer evenly distributed among the teeth, thus potentially creating hot spots inside the machine. The model proposed can, therefore, serve as a basis to assess the overall magnetic losses and the load capacity under fault, given that the field distribution, as well as its associated effects, is essential to establish the machine capacity under unbalance.
More Related Videos
Related Concept Videos
Inductance: Single-Phase And Three-Phase Line
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...
Power Distribution in Three-phase and Single Phase Circuits
Single-Phase Power Distribution:
Single-phase circuits are typical in household settings;...
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Phase Diagrams
Phase Transitions
Capacitance: Single-Phase And Three-Phase Line
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...