Related Experiment Video
Updated: Jan 23, 2026

A Standard and Reliable Method to Fabricate Two-Dimensional Nanoelectronics
Published on: August 28, 2018
Incorporation of 3D stereophotogrammetry as a reliable method for assessing scar volume in standard clinical practice
Mitchell Peake1, Kristen Pan1, R Maxwell Rotatori1
1Shriners Hospitals for Children, Cincinnati, United States; University of Cincinnati College of Medicine, United States.
Abstract:
Significant disfigurement and dysfunction is caused by hypertrophic scarring, a prevalent complication of burn wounds. A lack of objective tools in the assessment of scar parameters makes evaluation of scar treatment modalities difficult. 3D stereophotogrammetry, obtaining measurements from 3D photographs, represents a method to quantitate scar volume, and a 3D camera may have use in clinical practice. To validate this method, scar models were created and photographed with a 3D camera. Measurements from 3D image analysis of these scar models were compared to physical measurements of scar model volume. Reliability of 3D image analysis was assessed with both scar models and burn patient scars. Measurements of scar models by two independent observers were compared to determine inter-rater reliability, and measurements from 3D images of burn patient hypertrophic scars were compared to determine the consistency of the method between observers. The time taken for patient photography was recorded. No significant differences were found between the two methods of volume calculation (p = 0.89), and a plot of the differences showed agreement between the methods. The correlation coefficient between the two observers' measurements of scar model volume was 0.92, and the intra-class correlation coefficient for patient scar volume was 0.998, showing good reliability. The time required to capture 3D photographs ranged from 2 to 6 min per patient, showing the potential for this tool to be efficiently incorporated into clinical practice. 3D stereophotogrammetry is a valid method to reliably measure scar volume and may be used to objectively measure efficacy of scar treatment modalities to track scar development and resolution.
Related Concept Videos
Reliability and Validity
Angina III: Clinical Manifestations and Assessment
Empirical Method to Interpret Standard Deviation
This rule is used widely in statistics to calculate the proportion of data values...
Measurement: Standard Units
Distribution Reliability and Automation
Clinically Relevant Drug Product Specifications: Methods of Establishment