Related Experiment Video
Updated: Jan 23, 2026

Simulation of the Planetary Interior Differentiation Processes in the Laboratory
Published on: November 15, 2013
Study of the capsule-filling dosator process via calibrated DEM simulations
Stefan Madlmeir1, Peter Loidolt2, Johannes G Khinast1
1Institute of Process and Particle Engineering, TU Graz, Inffeldgasse 13, 8010 Graz, Austria; Research Center Pharmaceutical Engineering, Inffeldgasse 13, 8010 Graz, Austria.
Abstract:
Capsule filling is frequently accomplished via the dosator process. Controlling the main quality attributes, i.e., the fill weight and the fill weight variability, requires excellent process understanding. For the investigation of critical process parameters of low-dose capsule filling, DEM simulations were used. Two contact models (Hertz model and Luding model) were calibrated and validated to represent the lactose powder Lactohale 100. Both models gave good results, yet the Luding model resulted in better predictions. Since the dosator process is a volume-based approach, the dosator geometry is an important factor. We provide evidence that not only the volume, but also the proportions of the dosator affect the capsule fill weight. Slim nozzle chambers cause lower mass due to increased wall friction impact. The process is not volumetric, as a fill weight to volume correlation does not exist. Furthermore, the fill weight increases with higher powder beds and smaller gaps between the nozzle tip and the container bottom due to higher densification of the powder. Fill weight variations due to bed inhomogeneity were investigated by varying the bulk density of the initial powder bed.
More Related Videos
Related Concept Videos
Formulation and Manufacturing Process: Physical Attributes of Generic Tablets and Capsules
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Plotting and Calibrating the Root Locus
The maximum gain occurs at the breakaway points between open-loop poles on the real axis, while the minimum gain is...
Calibration Curves: Correlation Coefficient
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...

