Related Experiment Video
Updated: Jan 23, 2026

Rup (RNA-seq Usability Assessment Pipeline) - Quality Control for Bulk RNA-seq Experiments in Eukaryotes
Published on: November 7, 2025
Performance assessment of extensive green roof runoff flow and quality control capacity based on pilot experiments
Yongwei Gong1, Dingkun Yin2, Junqi Li1
1Key Laboratory of Urban Stormwater System and Water Environment, Ministry of Education, Beijing University of Civil Engineering and Architecture, Beijing 100044, China; Beijing Advanced Innovation Center of Urban Design for Future Cities, Beijing 100044, China.
Abstract:
Green roof is an important measure in "Sponge Cities" to reduce the runoff and improve the runoff quality. The runoff quantity and quality control capacity of five types of extensive green roofs (EGRs) were analyzed in Beijing for 51 nature rainfall events and 6 simulated events from July 2017 to October 2018. Different module scales (sizes) and substrate depths were examined to study their correlation to runoff retention, peak flow reduction, pollutant event mean concentration (EMC) and load reduction performance of EGRs. In general, both the single-field rainfall events and the long-term monitoring showed that as the module scale and substrate thickness increased, the retention capacity of the EGRs increased. As the module scale increased, the peak flow reduction rate (Pfrr) of the EGR modules increased, while the thickness of the substrate appeared to have less of an effect on Pfrr. When water quality effect was considered, compared with module scale, the substrate thickness had a more obvious effect on the average EMC of different pollutants. As the substrate thickness increased, the EMC of pollutants decreased. Under six simulated design rainfalls, EMC reduction rate of suspended solid (SS) of all types of EGRs ranged from 64.3%-73.1% while no reduction was found in the EMC of chemical oxygen demand (COD). The EMC trends of ammonia nitrogen (NH4+-N), nitrate nitrogen (NO3--N), total nitrogen (TN) and total phosphorus (TP) were almost the same, and their EMCs decreased with increasing total rainfall depth. When the pollutant load was considered, the EGRs in this study were a sink of NH4+-N, NO3--N, TN, and TP but a source of COD.
Related Concept Videos
Quality Control
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...
Controls in Experiments
Lung Capacity
Control of Power Flow
Pilot and Numeric Relaying
Design Example: Analyzing Capacity Contours for Flood Risk Assessment

