Accuracy of displayed volume with three airway sensors in an animal model
Mark J Heulitt1, Shirley J Holt2, Tracy L Thurman1
1Section of Critical Care Medicine, Department of Pediatrics, College of Medicine, University of Arkansas for Medical Sciences, Little Rock, AR, USA.
Abstract:
Optimal mechanical ventilation in infants and pediatrics depends on the reliability of flow sensors to correctly measure flow and integrate it into accurately displayed tidal volumes (V TE ). However, reliability of these devices has not been established. We hypothesize that reliability would be affected by both the type of flow sensors and ventilator controllers utilized. Intubated, sedated Sprague Dawley rats (n = 14) were ventilated (control and support modes) utilizing two different ventilators: 1) fixed orifice flow sensor (FOF) and 2) both a hot wire (HWF) and variable orifice flow sensor (VOF), independently. Accuracy of delivered tidal volume was obtained by comparing the displayed volume of the different sensors to breath waveforms acquired using a heated 0-5 L/min calibrated pneumotachograph. Analysis was performed utilizing ANOVA with P ≤ 0.05. Rats mean weight was 472 ± 46 g. For all modes, mean V TE % difference was demonstrated across all three measuring sensors. For volume control ventilation and pressure control ventilation or time cycled pressure limited assist control, there was a difference between all three sensors. For pressure support ventilation, there was a difference with the HWF only. R-square values were FOF 0.80, HWF 0.54, and VOF 0.16. The accuracy of delivered V TE is affected by both the flow sensor and ventilator controller to deliver the breath. We speculate that the flow sensor and the controller are associated with varying degrees of flow accuracy and control. We would expect volume accuracy for all modes to be equal if the flow accuracy were related to the inaccuracy of the flow sensors only.
Related Concept Videos
Improving Translational Accuracy
Improving Translational Accuracy
Uncertainty in Measurement: Accuracy and Precision
Accuracy and Precision
Accuracy, limits, and approximation
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...