Related Experiment Video
Updated: Jan 23, 2026

Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Targeting Noninducible Clinical Ventricular Tachycardias in Patients With Prior Myocardial Infarctions Based on
Miki Yokokawa1, Hyungjin Myra Kim1, Ghaith Sharaf Dabbagh1
1Division of Cardiovascular Medicine, Cardiac Arrhythmia Service, University of Michigan, Ann Arbor.
Background:
Ablation of postinfarction ventricular tachycardia (VT) has been shown to reduce VT recurrence and decrease mortality. However, VT recurrence can occur despite extensive ablation procedures. The lack of inducibility of clinical VTs during ablation procedures remains problematic and may be in part responsible for VT recurrences. In this prospective study, we targeted documented but noninducible clinical VTs based on stored implantable cardioverter-defibrillator (ICD) electrograms.
Methods:
Radiofrequency ablation was performed in a consecutive group of 66 postinfarction patients (mean age, 67.5±9.2 years; men, 61; mean left ventricular ejection fraction, 25.1±10.8%) in whom clinical VTs were not inducible during an ablation procedure. In the first 33 patients (control group), only inducible VTs were targeted, and in the second 33 patients, noninducible clinical VTs were also targeted by pace-mapping based on stored ICD-electrograms (ICD-electrogram-guided ablation group). Procedural and clinical outcomes were compared at 24 months post-ablation.
Results:
VT recurred in 5 patients (15%) in whom the ICD-electrogram-guided approach was performed and in 13 patients (39%) in the control group. Freedom from recurrent VT was higher (log-rank P=0.04) in the ICD-electrogram-guided group, but there was no difference in ventricular fibrillation or in total mortality between both groups.
Conclusions:
Ablation guided by pace-mapping of noninducible postinfarction clinical VTs based on ICD-electrograms is feasible and reduces the risk of recurrent VT.
Related Concept Videos
Energy Stored in a Capacitor
Energy Stored in Capacitors
By integrating the equation that relates voltage and current in a capacitor, one can derive an equation for the voltage across the capacitor at any given time. This equation is crucial in understanding and predicting the behavior of capacitors in...
Energy Stored in Inductors
In terms of gauging the energy stored within an inductor, it is equivalent to the integral of the power delivered at every individual moment, all...
Energy Stored in a Capacitor: Problem Solving
Capacitor-discharge ignition is a type of ignition system commonly found in small engines where the energy released from a capacitor ignites an induction coil that, in turn, fires the spark plug.
To calculate the energy stored in a capacitor of...
Energy Stored In A Coaxial Cable
In the simplest form, a coaxial cable can be represented by two long hollow concentric cylinders in which the current flows in opposite directions. The magnetic field inside and outside the coaxial cable is determined by using Ampère's law. The magnetic field inside...
Nursing Clinical Information System
A Nursing Clinical Information System (NCIS) is a specialized type of healthcare information system tailored to meet the unique needs of nursing practice. It incorporates the principles of nursing informatics to streamline information management and improve the quality of care delivery.
Critical attributes of NCIS include: