Related Experiment Video
Updated: Jan 23, 2026

Electrochemical Preparation of Poly3,4-Ethylenedioxythiophene Layers on Gold Microelectrodes for Uric Acid-Sensing Applications
Published on: July 28, 2021
Fabrication of an efficient and sensitive colorimetric biosensor based on Uricase/ Th-MOF for uric acid sensing in
Arastoo Badoei-Dalfard1, Nasrin Sohrabi1, Zahra Karami1
1Department of Biology, Faculty of Sciences, Shahid Bahonar University of Kerman, Kerman, Iran.
Abstract:
Recently, nanomaterial-based artificial enzymes have expected abundant consideration because of cheap, accessibility, and respectable stability. In this study, we report a Th-MOF artificial peroxidase, which can oxidize 3,3,5,5-tetramethylbenzidine by hydrogen peroxide to yield a blue product. The catalytic behavior of Th-MOF tracked Michaelis-Menten equation and the affinity of this nanozyme to the substrate was higher than horseradish peroxidase as a natural enzyme. The absorbance value of oxidized TMB is linearly associated with the hydrogen peroxide concentration. Since, hydrogen peroxide is the oxidative end product of uric acid (UA) by uricase, an efficient and sensitive approach for uric acid determination was also established. Results showed that Km value of Th-MOF with TMB as a substrate is much lower than that of other mentioned catalysts. The linear regression equations for uric acid substrate was stated as A = 0.0039C + 0.0519 with a correlation coefficient of 0.9955. The linear range for uric acid was from 4.0 to 70 μM, and the LOD was measured as 1.15 μM. Furthermore the absorbance of assay reaction was approximately constant in the following four cycles, demonstrating that Th-MOF catalyst has outstanding stability. Results showed that the public interfering substances had no obvious absorbance values and it was less than 0.1. Results indicated that the recoveries for UA in serum fluids were between 93.10% and 99.04%. The relative standard deviation (RSD, n = 3) at each concentration value was less than 4.3%. UA determination in serum fluids has been confirmed through a comparison between the recommended technique and tedious clinical approaches. Good recovery and accuracy of UA measurement indicated that this established colorimetric sensing system is appropriate for UA revealing in actual experimental samples.
More Related Videos
12:20Fabrication of Carbon Nanotube High-Frequency Nanoelectronic Biosensor for Sensing in High Ionic Strength Solutions
Published on: July 22, 2013
13:15Fabrication of Electrochemical-DNA Biosensors for the Reagentless Detection of Nucleic Acids, Proteins and Small Molecules
Published on: June 1, 2011
Related Concept Videos
Lewis Acids and Bases
A coordinate covalent bond (or dative bond) occurs when one of the atoms in the bond provides both bonding electrons. For example, a coordinate covalent bond occurs when a water molecule combines with a hydrogen ion to form a hydronium ion. A coordinate covalent bond also results when...
Ions as Acids and Bases
Salts are ionic compounds composed of cations and anions, either of which may be capable of undergoing an acid or base ionization reaction with water. Aqueous salt solutions, therefore, may be acidic, basic, or neutral, depending on the relative acid-base strengths of the salt’s constituent ions. For example, dissolving the ammonium chloride in water results in its dissociation, as described by the equation:
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Acids, Bases and Neutralization Reactions
Bronsted-Lowry Acids and Bases
Acid-Base Titration Curves