Quantification of pulsed saturation transfer at 1.5T and 3T
Rachel W Chan1, Sten Myrehaug2,3, Greg J Stanisz1,4,5
1Department of Physical Sciences, Sunnybrook Research Institute, Toronto, Canada.
Purpose:
To compare magnetization transfer (MT) and CEST effects between 1.5T and 3T in phantom and in vivo experiments.
Methods:
A pulsed saturation scheme using block-shaped pulses separated by gaps was used to overcome the single RF amplifier duty cycle limitations of a clinical 1.5T scanner. Modeling was performed by incorporating the extended phase graph formalism into a Bloch-McConnell simulation. Two saturation pulse types (with long and short pulses) were used. Estimated parameters for MT (the semi-solid pool fraction, M0B ; the semi-solid transverse relaxation time, T2B ) and CEST (asymmetry; areas) were compared between 1.5T and 3T in phantoms and in the healthy brain.
Results:
Improved fits were shown after inclusion of extended phase graphs. Semi-solid pool fractions in phantom (for agar with ammonium chloride) were higher for short compared to long pulses at 3T (by 19% over all concentrations) and higher at 1.5T compared to 3T (by 5%) using short pulses. In the in vivo experiments, differentiation of white and gray matter was seen in the brain at both field strengths with improved white-gray matter contrast at 3T. In white matter, the mean semi-solid fractions were 18 ± 2% at 3T and 15 ± 2% at 1.5T. The CEST asymmetry in white matter was negative (-4.9 ± 0.4%) at 3T and zero (0.0 ± 0.3%) at 1.5T.
Conclusions:
The pulsed saturation method with short pulses, using the extended phase graph formalism in the Bloch McConnell simulations, led to improved model fits to the data, when compared to those without extended phase graphs.
More Related Videos
05:37Rapid in-silico Battery Electrolyte Electrochemical Reaction Generation using 3T-VASP Multi-Scale Energy Minimization
Published on: August 22, 2025
04:46Changing the Direction and Orientation of Electric Field During Electric Pulses Application Improves Plasmid Gene Transfer in vitro
Published on: September 12, 2011
Related Concept Videos
Solution Equilibrium and Saturation
Pulse
The pulse serves as a clinical...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...