Related Experiment Video
Updated: Jan 23, 2026

Surgical Swine Model of Chronic Cardiac Ischemia Treated by Off-Pump Coronary Artery Bypass Graft Surgery
Published on: March 27, 2018
Differences of early immunological responses in on-pump versus off-pump cardiac surgery
Sven Lehmann1, Maja-Theresa Dieterlen1, Anja Flister1
1Department of Cardiac Surgery, Heart Center, HELIOS Clinic, University Hospital Leipzig, Leipzig, Germany.
Introduction:
Cardiopulmonary bypass surgery is accompanied by an inflammatory response and pulmonary dysfunction that renders patients vulnerable to postoperative complications. The majority of studies investigating the inflammatory response in cardiopulmonary bypass focus on cytokine measurements. This study investigated the early response of peripheral blood cell types and early changes in lung tissue in on-pump versus off-pump cardiopulmonary bypass surgery.
Methods:
Landrace pigs were assigned to the following groups (n = 6 per group): 1. off-pump cardiopulmonary bypass, 2. conventional cardiopulmonary bypass, 3. heparin-coated cardiopulmonary bypass, 4. surface-reduced cardiopulmonary bypass, and 5. surface-reduced cardiopulmonary bypass plus lung perfusion. Surgery was performed under mild hyperthermia (32°C), with 90-minute ischemia and 180-minute reperfusion. Histological and flow cytometric analyses were performed.
Results:
Lung water content increased during reperfusion in heparin-coated (84.63 ± 2.99%) compared to conventional cardiopulmonary bypass (76.33 ± 4.56%, p = 0.04). Alveolar septal thickness increased during ischemia at heparin-coated (p < 0.01) and surface-reduced cardiopulmonary bypass plus lung perfusion (p = 0.05). Tumor necrosis factor expression increased significantly (p < 0.01) in peribronchial, perivascular, and peripheral lung areas in all on-pump groups, but not in off-pump cardiopulmonary bypass. The usage of heparin-coated cardiopulmonary bypass led to increased percentages of CD3+CD4+ (p = 0.03) and CD3+CD8+ (p = 0.01) T cells compared to an uncoated device. Natural killer and mature B lymphocytes decreased at conventional and surface-reduced cardiopulmonary bypass plus lung perfusion. Activated granulocytes and macrophages increased at conventional cardiopulmonary bypass and heparin-coated cardiopulmonary bypass.
Conclusion:
Off-pump cardiopulmonary bypass induces less immunological response and lung injury than on-pump surgery. The reduction of cardiopulmonary bypass surface reduces the inflammatory immune response induced by cardiopulmonary bypass. Lung perfusion of surface-reduced cardiopulmonary bypass diminished the extravasation caused by surface reduction of the cardiopulmonary bypass.
Related Concept Videos
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Pumped Concrete
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
Refrigerators and Heat Pumps
A household refrigerator removes heat from...
ATP Driven Pumps I: An Overview
There are four main types of ATP-driven pumps - P-type, V-type, F-type, and ABC transporter. All these pumps are of varying complexities and...
Acid Suppressive Drugs for Peptic Ulcer Disease: Proton Pump Inhibitors
Gastric acid, a potent cocktail of hydrogen and chloride ions, is produced in specialized parietal cells within the...

