Comparison of Efficiency and Image Quality of Photostimulable Phosphor Plate and Charge-Coupled Device Receptors in
Wenjian Zhang1, Carolyn Huynh2, Aniket Jadhav2
1Wenjian Zhang is Associate Professor, Department of Diagnostic and Biomedical Sciences, University of Texas School of Dentistry at Houston; Carolyn Huynh is Associate Professor, Department of Diagnostic and Biomedical Sciences, University of Texas School of Dentistry at Houston; Aniket Jadhav is Assistant Professor, Department of Diagnostic and Biomedical Sciences, University of Texas School of Dentistry at Houston; Jose Pinales is Dental Radiologic Technologist III, Department of Patient Care, University of Texas School of Dentistry at Houston; Liliana Arvizu is Dental Radiologic Technologist III, Department of Patient Care, University of Texas School of Dentistry at Houston; Jenny Tsai is Dental Radiologic Technologist I, Department of Patient Care, University of Texas School of Dentistry at Houston; and Nidia Flores is Dental Radiologic Technologist I, Department of Patient Care, University of Texas School of Dentistry at Houston. Wenjian.Zhang@uth.tmc.edu.
Abstract:
The photostimulable phosphor (PSP) plate and charge-coupled device (CCD) are receptors commonly used for intraoral radiography in U.S. dental schools. However, it is unclear which receptor is more beneficial for radiology education and patient care in an academic setting. The aim of this study was to compare the time efficiency, image quality, and operator performance for student-operated PSP plate and CCD receptors. At one U.S. dental school in 2018, 20 dental hygiene and dental students (n=10 each) were recruited as operators. They each exposed anterior and posterior periapical and bitewing radiographs on dental radiograph teaching and training replica using the PSP plate and CCD as receptors. The time taken to expose the radiographs was recorded. Image sharpness/definition, brightness/contrast, and technical errors, including placement, angulation, and cone cut errors, were evaluated on a three-point scale with 0=non-diagnostic, 1=diagnostic acceptable with minor errors, and 2=perfect diagnostic quality. The results showed that it was generally faster for the students to expose intraoral radiographs with CCDs than with PSP plates, although the difference was not significant (p>0.05). Image quality and technical accuracy, especially angulation, were significantly superior for PSP relative to CCD (p<0.05). This study found that PSP imaging was of higher quality and accuracy than CCD, whereas CCD was more efficient. Dental and dental hygiene students would benefit from being trained on both receptors to be able to adapt to a diversified workplace.
More Related Videos
Related Concept Videos
G-protein Coupled Receptors
G Protein-coupled Receptors
GPCRs are also called heptahelical, 7TM, or serpentine receptors, and consist of seven (H1-H7) transmembrane alpha-helices that span the bilayer to form a cylindrical core. The transmembrane helices are connected by three extracellular loops and three...
Column Efficiency: Plate Theory
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...
Formal Charges
Transducer Mechanism: G Protein–Coupled Receptors
GPCRs are also called heptahelical,...
Ions and Ionic Charges