Related Experiment Video
Updated: Jan 23, 2026

Determining Glucose Metabolism Kinetics Using 18F-FDG Micro-PET/CT
Published on: May 2, 2017
Primary Central Nervous System Lymphoma: Diagnostic Yield of Whole-Body CT and FDG PET/CT for Initial Systemic
Chong Hyun Suh1, Ho Sung Kim1, Ji Eun Park1
1From the Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Olympic-ro 33, Seoul 05505, Republic of Korea.
Abstract:
Background Updated guidelines for suspected primary central nervous system lymphoma (PCNSL) are lacking. Purpose To investigate the diagnostic yield of initial systemic imaging in patients suspected of having PCNSL by using contrast material-enhanced chest and abdominopelvic CT and/or whole-body fluorine 18 fluorodeoxyglucose (FDG) PET/CT. Materials and Methods This retrospective study included 304 patients examined at a single tertiary hospital between January 1998 and October 2018. Consecutive adults (age >18 years) who were confirmed to have newly diagnosed PCNSL on the basis of findings at stereotactic brain biopsy were recruited. All patients were examined with contrast-enhanced chest and abdominopelvic CT and/or whole-body FDG PET/CT before initiation of PCNSL treatment. The diagnostic yield of CT and PET/CT was determined before therapy and at the time of recurrence in the brain. A χ2 test was performed to compare the diagnostic yield according to study date in order to assess for possible changes in technology during the study period. Results A total of 304 patients (180 men with a mean age [±standard deviation] of 58 years ± 13 and 124 women with a mean age of 59 years ± 13) were included. The diagnostic yield of CT and PET/CT for initial staging was 2% (six of 304 patients; 95% confidence interval [CI]: 0.7%, 4.3%), and these tests yielded false-positive findings in 13 of the 304 patients (4%; 95% CI: 2.3%, 7.2%). Diagnostic yield did not differ between patients evaluated before 2009 and those evaluated in 2009 and later (P = .82). The diagnostic yield of systemic imaging at recurrence was 1.5% (one of 68 patients; 95% CI: 0.0%, 7.9%), and these tests yielded false-positive findings in four of those 68 patients (6%; 95% CI: 1.6%, 14.4%). Conclusion Contrast-enhanced chest and abdominopelvic CT and/or whole-body fluorine 18 fluorodeoxyglucose PET/CT for initial staging, as well as for recurrence of suspected primary central nervous system lymphoma, had a low diagnostic yield. © RSNA, 2019 See also the editorial by Jara in this issue.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Radiological Investigation I: X-ray and CT
Buffer Systems in the Body
A typical buffer system in bodily fluids includes a weak acid and its corresponding...
What is a Nervous System?