Model-based glycemic control in a Malaysian intensive care unit: performance and safety study
Asma Abu-Samah1, Jennifer Launa Knopp2, Normy Norfiza Abdul Razak3
1Institute of Energy Infrastructure, Universiti Tenaga Nasional, Kajang, 43000, Malaysia.
The STAR protocol effectively managed blood glucose in critically ill patients, showing good safety. Adaptations may be needed for optimal performance in the Malaysian healthcare setting.
Area of Science:
- Critical Care Medicine
- Endocrinology
- Health Informatics
Background:
- Stress-induced hyperglycemia is a frequent complication in critically ill patients.
- Model-based glycemic control, such as the STAR protocol, offers a potential solution.
- The STAR protocol has been utilized in intensive care units (ICUs) internationally since 2010.
Purpose of the Study:
- To pilot test the STAR protocol's performance and safety in a Malaysian ICU.
- To assess the adaptability of the model-based glycemic control framework in a new healthcare environment.
- To evaluate the feasibility of implementing automated glycemic control in the International Islamic University Malaysia Medical Centre (IIUMMC) Hospital ICU.
Main Methods:
- A pilot trial involving 142 patients who underwent STAR protocol treatment for over 20 hours.
- Analysis of blood glucose measurements to assess performance within target bands and incidence of hypoglycemia.
- Evaluation of clinical staff preferences and treatment intervention frequency.
Main Results:
- 60.7% of blood glucose measurements fell within the target range.
- Hypoglycemia rates were low, with 0.78% below 4.0 mmol/L and 0.02% below 2.2 mmol/L.
- While nurses found the protocol beneficial for workload reduction, performance indicated a need for control setting adjustments.
Conclusions:
- The STAR protocol demonstrated success in achieving patient-specific glycemic control and ensuring safety.
- The protocol was well-received by nursing staff, contributing to reduced workload.
- Performance data suggests that modifications to the control settings are necessary for optimal adaptation to the Malaysian context.
More Related Videos
Related Concept Videos
Measurement: Derived Units
Per-Unit Sequence Models
Zero-sequence currents, which are identical in magnitude and phase, generate a neutral current, resulting in voltage drops across the neutral impedance and the low-voltage winding. If the...
Measurement: Standard Units
Survey Safety
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Varicose Veins II: Diagnostic Studies and Interprofessional Care