Related Experiment Video
Updated: Jan 23, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Multimodal imaging of aortic annulus and root geometry after valve sparing root reconstruction
Matthew Valdis1, Andrew Thain2, Philip M Jones3,4
1Division of Cardiac Surgery, Department of Surgery, Western University, London Health Sciences Centre, London, Ontario, Canada.
Background:
Controversy exists regarding the optimal annular stabilization technique following valve sparing aortic root reconstruction (VSRR) with no comprehensive imaging data to evaluate the natural history of aortic root graft geometry, aortic valve competency and patient prognosis post-reconstruction.
Methods:
Between 2008-2017, 70 consecutive patients (mean age 56.4±16.4 years, 19.7% females) underwent VSRR. All patients were prospectively evaluated annually with clinical follow-up, echocardiography and CT imaging. Patients were assessed for survival, freedom from reoperation, degree of regurgitation, New York Heart Association (NYHA) status and graft complications and followed up to nine years post-operatively (mean 36±21 months).
Results:
The largest increase of the aortic annulus diameter observed during the surveillance period was 2.64%±5.4% which occurred between the second and third years of follow-up and the aortic sinuses, sinotubular junction and ascending aorta all remained relatively stable based on annual CT imaging. Echocardiographic data showed far more variability in measurements at each annual post-operative visit with far less precision compared to the CT measurements taken at the same time. Due to the large variability and greater standard deviations, no significant difference was detected between the more precise CT measurements and those from the echocardiogram images. The overall survival rate was 94.3% (66 patients) at one year. Freedom from reoperation was 98.6% (69 patients). Throughout the entire duration of follow-up, aortic insufficiency was identified as 0 in 46 (65.7%), 1+ in 19 (27.1%), 2+ in 4 (5.7%), 3+ in 0 (0%) and 4+ in 1 (1.4%). Mean NYHA status was 1.1±0.3 at most recent follow-up for all patients. CT evidence showed 97.0% (64 patients) freedom from graft complication including: endocarditis, thrombosis, embolism, aneurysm, pseudoaneurysm, dehiscence, dissection and kinking.
Conclusions:
The annual imaging data presented here demonstrates stability of the Dacron aortic annuloplasty reconstruction over time, without the need for internal or external annular stabilization. CT imaging proved to be far more reliable than echocardiographic images, however given the stability, annual CT imaging is of little benefit. This is the first prospective study to compare echocardiographic, CT and clinical data following VSRR.
More Related Videos
Related Concept Videos
Primary and Secondary Growth in Roots and Shoots
Root Mean Square
For example, consider the velocity of gas molecules in a container. The gas molecules are moving in different directions, which might impart positive and negative...
Root-Locus Method
This system can be represented by a block...
Construction of Root Locus
For positive gain values, the root locus exists on the real axis to the left of an odd number of finite open-loop poles or zeros. The root locus starts at the open-loop poles and traces the paths of the closed-loop poles as the gain...
Properties of the Root Locus
To determine if a point lies on the root locus, the criterion involves the sum of angles contributed by all poles and zeros to that point. Specifically, this sum must be an odd multiple of 180 degrees. The gain at any point on...
Plotting and Calibrating the Root Locus
The maximum gain occurs at the breakaway points between open-loop poles on the real axis, while the minimum gain is...

