Guidelines for Selection of Internal Standard-Based Normalization Strategies in Untargeted Lipidomic Profiling by
Bernhard Drotleff1, Michael Lämmerhofer1
1Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis , University of Tübingen , Tübingen 72076 , Germany.
Abstract:
Due to variation in instrument response caused by various sources of errors throughout an analytical assay, data normalization plays an indispensable role in untargeted LC-MS profiling, yet limited accepted guidelines on this topic exist. In this work, a systematic comparison of several normalization techniques, mainly focusing on internal standard-based approaches, has been performed to derive some general recommendations. For generation of untargeted lipidomic data, a comprehensive ultra-high performance liquid chromatography (UHPLC)-electrospray ionization (ESI)-quadrupole time of flight (QTOF)-MS/MS method was utilized. To monitor instrument stability and evaluate normalization performance, quality control (QC) samples, prepared from aliquots of all experimental samples, were embedded in the sequence. Stable isotope labeled standards, representing differing lipid classes, were spiked to each sample as internal standards for postacquisition normalization. Various metrics were used to compare distinct normalization strategies, with reduction of variation in QC samples being the critical requirement for acceptance of successful normalization. The comparison of intragroup coefficients of variation (CVs), median absolute deviations (MADs), and variance enables simple selection of the best performance of normalization with improved and coherent results. Furthermore, the importance for normalization in critical data sets, showing only minor effects between groups with high variation and outliers, is pointed out. Apart from normalization, also, influences of used raw data types are demonstrated. In addition, effects of various factors throughout the processing workflow were investigated and optimized. Eventually, implementation of quality control samples, even if not required for normalization, provided a useful basis for assessing data quality. Due to lack of consensus for selecting optimum normalization, suggestions for validating data integrity are given.
More Related Videos
Related Concept Videos
Guidelines and Strategies for Safe Computer Charting
Maintain Confidentiality and Security:
Variation: Normal Distribution, Range, and Standard Deviation
Measurement: Standard Units
Internal Energy
Internal Receptors
Guidelines for Nursing Documentation II
Timely documentation is crucial to ensure continuity of care for patients. Any delays in recording or reporting medical information can result in medical errors and even adverse patient outcomes. From medication administration to diagnostic test results, every detail must be accurately and promptly documented to provide the best possible care for patients.