Related Experiment Video
Updated: Jan 22, 2026

Construction and Characterization of External Cavity Diode Lasers for Atomic Physics
Published on: April 24, 2014
Simultaneous and interference-free measurements of temperature and C2H4 concentration using a single tunable diode
Abstract:
In the tunable diode laser absorption spectroscopy-based diagnostics, the absorption of the measured target species may be influenced by the interference absorption from other vapor-phase species and the extinction from particles and liquid droplets, especially at high temperatures and pressures. Here, we report the first application (to our knowledge) of a differential absorption diagnostic for interference-free, simultaneous measurement of temperature and ethylene concentration using a single distributed-feedback diode laser near 1.62 μm. According to the detailed study of the C2H4 spectra in this region, two wavelength pairs are chosen to measure the temperature based on six selection criteria. C2H4 concentration is measured by one of the selected wavelength pairs with higher differential absorption. To validate the developed system, experiments are performed in a well-controlled heated static cell at a range of temperatures (300-900 K) and pressures (1-6 atm). The measurement accuracies for temperature and ethylene concentration are 1.83% and 1.65%, respectively, over the considered ranges. The precision, stability, and detection limit are also analyzed to validate the system's performance. This system can potentially be applied in a variety of combustion applications.
Related Concept Videos
Drug Concentrations: Measurements
Plasma...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Interference and Diffraction
RNA Interference
This process occurs naturally in cells, often through the activity of genomically-encoded microRNAs. Researchers can take advantage of this mechanism by introducing synthetic RNAs to deactivate specific genes for research or therapeutic purposes. For example, RNAi could be used...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Zener Diodes

