Related Experiment Video
Updated: Jan 22, 2026

A Mouse Model of Orthopedic Surgery to Study Postoperative Cognitive Dysfunction and Tissue Regeneration
Published on: February 27, 2018
Assessment of Changes in Body Composition During the First Postoperative Year After Bariatric Surgery
Fernanda Guidi Colossi de Paris1, Alexandre Vontobel Padoin2, Cláudio Corá Mottin2
1Faculdade de Medicina, Pontificia Universidade Catolica do Rio Grande do Sul, Porto Alegre, Brazil. fefagcp@hotmail.com.
Background:
The potential effect of bariatric surgery on weight reduction and improvement of associated comorbidities is known, but the ratio obtained between the components of body weight, including lean body mass, body fat mass, and bone mass, is still not determined. This study aims to verify the changes in body composition during the first year after bariatric surgery.
Methods:
We conducted a prospective observational cohort study. Fifty patients who underwent bariatric surgery and maintained follow-ups were selected. Patients were assessed preoperatively and postoperatively for periods of 1, 3, 6, and 12 months using tetrapolar bioelectrical impedance analysis and laboratory testing of lipids and serum albumin levels. Data were statistically analyzed.
Results:
Statistically significant differences (p < 0.001) were obtained between the preoperative and 12-month evaluation respectively, for body mass index (BMI) (45.8 ± 7.5 to 30.0 ± 4.8 kg/m2), FM (64.7 ± 15.5 to 30.6 ± 9.8 kg), PFM (51.6 ± 4.17 to 37.3 ± 7.6%), and total cholesterol levels (197.1 ± 49.8 to 169.8 ± 31.0 mg/dL). The decrease in PFM shows a better proportion between the body components. PFM showed significantly higher decrease in males than in females (p = 0.012). Lean body mass (p = 0.000) reduction was highest for patients operated by the Unified Health System (SUS, Government of Brazil) probably because of its few financial resources to maintain postoperative care.
Conclusion:
The change in body composition of patients who underwent Roux-en-Y gastric bypass was statistically significant for all variables examined during the first year postoperatively. This shows the effectiveness of the surgical procedure and clinical protocol set, which tends to favor a better health prognosis and weight maintenance in the long term.
More Related Videos
08:22Using Deuterium Oxide as a Non-Invasive, Non-Lethal Tool for Assessing Body Composition and Water Consumption in Mammals
Published on: February 20, 2020
06:48Author Spotlight: Advancements in 3D Optical Imaging for Comprehensive Body Composition Assessment in Modern Research
Published on: June 7, 2024
Related Concept Videos
Composite Bodies
Composite bodies have widespread applications in mechanical engineering, from automobiles to aircraft to rockets. For example, an automobile wheel comprises...
Composition of Body Fluids
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...