Related Experiment Video
Updated: Jan 22, 2026

In Vitro Thrombosis Test for Ventricular Assist Devices
Published on: March 21, 2025
Flow Pattern of Outflow Graft is Useful for Detecting Pump Thrombosis in a Patient with Left Ventricular Assist
Tasuku Sato1,2, Takeo Fujino3, Taiki Higo4
1Heart Center, Kyushu University Hospital.
Abstract:
Pump thrombosis (PT) is a serious complication after continuous-flow left ventricular assist device (LVAD) implantation. To detect PT, echocardiographic ramp test using left ventricular end-diastolic diameter (LVEDD) is known to be useful. However, this method has several limitations. In this study, we propose an alternative novel ramp test using the flow velocity of outflow graft (OG). A 46-year-old man underwent continuous-flow LVAD (HeartMate II, Abbott Laboratories, Lake Forest, IL, USA) implantation for advanced heart failure due to idiopathic dilated cardiomyopathy. About 2 years after implantation, he suffered from hemolysis and symptoms of heart failure, and PT was strongly suspected. The change in LVEDD was minimal with increase in pump speed (-0.06 cm/400 rotations per minute (rpm)), suggesting PT. The systolic to diastolic velocity (S/D) ratio of OG flow, which we proposed as a new indicator of PT, also showed minimal change (-0.07/400 rpm). His clinical symptoms improved with anticoagulation therapy, and the changing slope of the S/D ratio dramatically improved to -0.92/400 rpm. Although its consistency should be verified in many other cases, this novel method can be useful for detecting PT and evaluating its clinical course.
Related Concept Videos
Venous Thrombosis I: Introduction
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Pumped Concrete
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
Refrigerators and Heat Pumps
A household refrigerator removes heat from...
Fixed Action Patterns

