Related Experiment Video
Updated: Jan 22, 2026

Novel and Innovative Hybrid Technique for Type A Aortic Dissection
Published on: March 28, 2025
Homemade Candy Plug Using a Zenith Alpha Thoracic Stent-Graft for False Lumen Distal Occlusion in Acute-on-Chronic
Kok Hooi Yap1, Yi Chuan Tham1, Kiang Hiong Tay1
1National Heart Centre Singapore, Singapore.
Abstract:
Purpose: To report a candy-plug technique using a Zenith Alpha stent-graft to occlude the distal false lumen in a patient with a complicated chronic type B aortic dissection. Case Report: A 50-year-old male smoker presented with chest pain due to rapidly growing complicated chronic type B aortic dissection. Computed tomography angiography (CTA) showed the dissection extending from distal to the origin of the left subclavian artery (LSA) down to the left femoral artery. There was fusiform aneurysmal dilatation of the proximal descending aorta measuring up to 5.8 cm in diameter. He underwent left carotid-subclavian artery bypass, thoracic endovascular aortic repair with a Zenith Alpha stent-graft, a left common carotid artery chimney, and embolization of the proximal LSA. Serial CTA showed persistent false lumen flow. A decision was made to occlude the distal large false lumen using the candy-plug technique. A 44×125-mm Zenith Alpha stent-graft was used to prepare the candy plug. A gutter leak and a type Ia endoleak were embolized via a left brachial artery approach. At 2.5 years, imaging showed the candy plug in position, no endoleak, and the thrombosed false lumen in the thoracic aorta reduced in size. Conclusion: The candy-plug technique is useful in facilitating complete occlusion of the false lumen in chronic aortic dissection, which avoids an open procedure and the risk of higher morbidity.
Related Concept Videos
Formation of the Platelet Plug
As the injured blood vessel contracts, endothelial cells undergo contraction, revealing collagen fibers in the basement membrane and underlying connective tissue. Furthermore, the plasma membrane of endothelial cells becomes adhesive, preparing the site for platelet adhesion. Platelets...
False Memories
One primary source of false memories is misattribution, where individuals incorrectly associate external information...
Thoracic Aorta
The Thoracic Cage: Sternum
The sternum is the elongated bony structure on the anterior side of the thoracic cage. It consists of three parts: the manubrium, the body, and the xiphoid...
The Thoracic Cage: Ribs
Parts of a Typical Rib
A typical rib has a head, neck, and body. The posterior end of the rib is called the head, followed by a narrow neck. The head articulates primarily with the costal...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...

