Related Experiment Video
Updated: Jan 22, 2026

Synthesis of Near-Infrared Emitting Gold Nanoclusters for Biological Applications
Published on: March 22, 2020
Bioactivity-Protected Electrochemiluminescence Biosensor Using Gold Nanoclusters as the Low-Potential Luminophor and
Yue Jia1, Lei Yang1, Jingwei Xue1
1Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering , University of Jinan , Jinan 250022 , China.
Abstract:
The expansion of electrochemiluminescence (ECL) technology to immunoassay at the core of care emphasizes all immune molecules will not be inactivated in the analysis process. That poses a major challenge to ECL-based biosensors due to the deoxynucleotide sequences of an antigen or antibody could be oxidized through a route of excessive cyclic potential. Herein, an ultrasensitive ECL biosensor was developed based on a novel bioactivity-protected sensing strategy utilizing Au nanoclusters (Au NCs) as low-potential luminophor for detection of procalcitonin (PCT). Bovine serum albumin (BSA)-templated Au NCs exhibited a low-potential anodic ECL signal in triethylamine (TEA) solution at 0.87 V, where it is suitable for the survival of immune molecules. Taking advantage of good conductivity and high surface area, a Cu2S snowflake not only functions as a satisfying substrate for connecting immune molecules but also acts as co-reaction accelerator to produce more cationic radicals TEA•+, which could improve the ECL intensity needed to meet the requirements of trace analysis. Otherwise, HWRGWVC (HC-7) heptapeptide as specific antibody immobilizer for site-oriented fixation was introduced to further maintain the bioactivity of an antibody. In view of the preceding discussion, the obtained biosensor exhibited ultrahigh immune recognition to targets so that the detection limit was as low as an unprecedented value of 2.36 fg/mL, which will be of great significance to the application and development of a biosensor in the future.
More Related Videos
08:26Luminophore Formation in Various Conformations of Bovine Serum Albumin by Binding of GoldIII
Published on: August 31, 2018
08:31Biosensor-based High Throughput Biopanning and Bioinformatics Analysis Strategy for the Global Validation of Drug-protein Interactions
Published on: December 1, 2020
Related Concept Videos
Relative Motion Analysis - Acceleration
Relative Motion Analysis using Rotating Axes - Acceleration
Time differentiation is...
Temperature Dependence on Reaction Rate
Atoms, molecules, or ions must collide before they can react with each other. Atoms must be close together to form chemical bonds. This premise is the basis for a theory that explains many observations regarding chemical kinetics, including factors affecting reaction rates.
The collision theory is based on the postulates that (i) the reaction rate is proportional to the rate of reactant collisions, (ii) the reacting species collide in an orientation allowing contact between...
Accelerators
The effectiveness of calcium chloride can...
Accelerating Fluids
The motion of the liquid within this infinitesimal cylinder is considered to obtain the pressure difference. Three vertical forces act on this liquid:
Instantaneous Acceleration