Related Experiment Video
Updated: Jan 22, 2026

The Role of Indocyanine Green Fluorescence in Complex Laparoscopic Cholecystectomy Navigation
Published on: January 31, 2025
Technical Note: Are Currently Used Measurements of Fluorescence Intensity in Near Infrared Fluorescence Imaging
Jacqueline van den Bos1,2, Rutger M Schols3, Sander M J van Kuijk4
1Department of Surgery, Reconstructive, and Hand Surgery, Maastricht University Medical Center, Maastricht, The Netherlands.
Abstract:
To investigate whether different calculation methods to express fluorescence intensity (FI) as target-to-background (BG) ratio are comparable and which method(s) match with human perception. Comparison of three calculation methods from current literature (OsiriX®, ImageJ®, and Photoshop®) to objectify FI during laparoscopic cholecystectomy measured at the exact same locations within recorded images of two categories: ex vivo and in vivo. Currently applied formulas to present FI in relation to the BG signal are compared with the subjective assessment by the human observers. These three formulas are Signal contrast = (FI in fluorescence regions-FI in BG)/255; Target-to-background ratio = (FI of target-FI of BG)/FI of BG; Signal-to-background ratio = FI of cystic duct/FI of liver and Target-to-background ratio = (FI of target-noise)/(FI of BG-noise). In our evaluation OsiriX and ImageJ provided similar results, whereas OsiriX values were structurally slightly lower compared with ImageJ. Values obtained through Photoshop were less evidently related to those obtained with OsiriX and ImageJ. The formula Target-to-background ratio = (FI of target-noise)/(FI of BG-noise) was less corresponding with human perception compared with the other used formulas. FI results based on measurements using the programs OsiriX and ImageJ are similar, allowing for comparison of results between these programs. Results using Photoshop differ significantly, making direct comparison impossible. This is an important finding when interpreting study results. We propose to report both target and BG FI in articles, so that proper interpretation between articles can be made.
More Related Videos
04:02Laparoscopic Cholecystectomy with Indocyanine Green Fluorescence: Choledochoscopic Stone Extraction and Primary Duct Suture
Published on: November 25, 2025
13:10Combined Near-infrared Fluorescent Imaging and Micro-computed Tomography for Directly Visualizing Cerebral Thromboemboli
Published on: September 25, 2016
Related Concept Videos
Photoluminescence: Fluorescence and Phosphorescence
A pair of electrons in a...
Atomic Fluorescence Spectroscopy
Confocal Fluorescence Microscopy
Variables Affecting Phosphorescence and Fluorescence
Fluorescence and Phosphorescence: Instrumentation
Super-resolution Fluorescence Microscopy