Development of advanced skin dose evaluation technique using a tetrahedral-mesh phantom in external beam
Bo-Wi Cheon1, Do-Hyeon Yoo1, Wook-Geun Shin1
1Department of Radiation Convergence Engineering, Yonsei University, Wonju 26493, Republic of Korea.
Abstract:
Incorrect prediction of skin dose in external beam radiotherapy (EBR) can have normal tissue complication such as acute skin desquamation and skin necrosis. The absorbed dose of skin should be evaluated within basal layer, placed between the epidermis and dermis layers. However, current treatment planning systems (TPS) cannot correctly define the skin layer because of the limitation of voxel resolution in computed tomography (CT). Recently, a new tetrahedral-mesh (TM) phantom was developed to evaluate radiation dose realistically. This study aims to develop a technique to evaluate realistic skin dose using the TM phantom in EBR. The TM phantom was modeled with thin skin layers, including the epidermis, basal layer, and dermis from CT images. Using the Geant4 toolkit, the simulation was performed to evaluate the skin dose according to the radiation treatment conditions. The skin dose was evaluated at a surface depth of 50 µm and 2000 µm. The difference in average skin dose between depths was up to 37%, depending on the thickness and region of the skin to be measured. The results indicate that the skin dose has been overestimated when the skin is evaluated using commercial TPS. Although it is not possible with traditional TPS, our skin dose evaluation technique can realistically express the absorbed dose at thin skin layers from a patient-specific phantom.
Related Concept Videos
Crystal Field Theory - Tetrahedral and Square Planar Complexes
Crystal field theory (CFT) is applicable to molecules in geometries other than octahedral. In octahedral complexes, the lobes of the dx2−y2 and dz2 orbitals point directly at the ligands. For tetrahedral complexes, the d orbitals remain in place, but with only four ligands located between the axes. None of the orbitals points directly at the tetrahedral ligands. However, the dx2−y2 and dz2 orbitals (along the Cartesian axes) overlap with the ligands less than the dxy,...
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Mesh Analysis
A fundamental concept in mesh analysis is the definition of meshes and mesh currents. A mesh is a closed...
Bioavailability Study Design: Single Versus Multiple Dose Studies
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...