Evaluation of Selected Essential Elements in Khalas Dates from Date Palm Determined by Inductively Coupled
Eid I Brima1,2
1Department of Chemistry, College of Science, King Khalid University, Abha 61413, Saudi Arabia.
Abstract:
In terms of nutrition, dates are an important commodity because they are a source of carbohydrates and minerals. Saudi Arabia is the second largest producer of dates worldwide. Khalas is the tenth most popular date type in the Kingdom of Saudi Arabia (KSA), but only limited information related to the levels of essential nutrients in Khalas dates is available. The concentrations of Mn, Cu, Zn, and Se were determined using inductively coupled plasma-mass spectrometry (ICP-MS). The average concentrations in wet weight were as follows (mg/kg): Mn (2.90 ± 0.54), Cu (1.78 ± 0.64), Zn (1.72 ± 0.42), and Se (0.10 ± 0.06). The calculated intakes (μg/kg bw day) per 100 g dates for each element were as follows: Mn (4.14), Cu (2.54), Zn (2.46), and Se (0.14), which represent 0.14%, 0.51%, 0.25%, and 0.2%, respectively, of the provisional maximum tolerable daily intake (PMTDI) recommended by the EFSA/WHO. It was found that levels of the analysed essential elements in up to 100 g of Khalas dates do not exceed the level set by the EFSA/WHO.
More Related Videos
11:18A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer SMPS-ICPMS
Published on: July 11, 2017
08:46Dose Uptake of Platinum- and Ruthenium-based Compound Exposure in Zebrafish by Inductively Coupled Plasma Mass Spectrometry with Broader Applications
Published on: April 21, 2022
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Key Elements for Plant Nutrition
Radioactive Decay and Radiometric Dating