Related Experiment Video
Updated: Jan 22, 2026

Mechanical Ventilation Boot Camp Curriculum
Published on: March 12, 2018
EIT monitors valid and robust regional ventilation distribution in pathologic ventilation states in porcine study
Sebastian D Reinartz1, Michael Imhoff2, René Tolba3
1Department of Diagnostic and Interventional Radiology, University Hospital, RWTH Aachen University, 52074, Aachen, Germany. sreinartz@ukaachen.de.
Abstract:
It is crucial to precisely monitor ventilation and correctly diagnose ventilation-related pathological states for averting lung collapse and lung failure in Intensive Care Unit (ICU) patients. Although Electrical Impedance Tomography (EIT) may deliver this information continuously and non-invasively at bedside, to date there are no studies that systematically compare EIT and Dual Energy CT (DECT) during inspiration and expiration (ΔDECT) regarding varying physiological and ICU-typical pathological conditions such as atelectasis. This study aims to prove the accuracy of EIT through quantitative identification and monitoring of pathological ventilation conditions on a four-quadrant basis using ΔDECT. In a cohort of 13 pigs, this study investigated systematic changes in tidal volume (TV) and positive end-expiratory pressure (PEEP) under physiological ventilation conditions. Pathological ventilation conditions were established experimentally by single-lung ventilation and pulmonary saline lavage. Spirometric data were compared to voxel-based entire lung ΔDECT, and EIT intensities were compared to ΔDECT of a 12-cm slab of the lung around the EIT belt, the so called ΔDECTBelt. To validate ΔDECT data with spirometry, a Pearson's correlation coefficient of 0.92 was found for 234 ventilation conditions. Comparing EIT intensity with ΔDECT(Belt), the correlation r = 0.84 was found. Normalized cross-correlation function (NCCF) between scaled global impedance (EIT) waveforms and global volume ventilator curves was r = 0.99 ± 0.003. The EIT technique correctly identified the ventilated lung in all cases of single-lung ventilation. In the four-quadrant based evaluation, which assesses the difference between end-expiratory lung volume (ΔEELV) and the corresponding parameter in EIT, i.e. the end-expiratory lung impedance (ΔEELI), the Pearson's correlation coefficient of 0.94 was found. The respective Pearson's correlation coefficients implies good to excellent concurrence between global and regional EIT ventilation data validated by ventilator spirometry and DECT imaging. By providing real-time images of the lung, EIT is a promising, EIT is a promising, clinically robust tool for bedside assessment of regional ventilation distribution and changes of end-expiratory lung volume.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Mechanical Ventilation I: Indication and Settings