Quantitative detection and evaluation of thrombus formation based on electrical impedance spectroscopy
Jianping Li1, Nen Wan1, Jianming Wen1
1Institute of Precision Machinery and Smart Structure, College of Engineering, Zhejiang Normal University, Jinhua, 321004, Zhejiang Province, China.
Abstract:
Thrombus formation is quantitatively measured and evaluated by the electrical impedance spectroscopy method in this study, which confirms the possibility for the application of a promising non-invasive thrombus detection method. The impedance parameter Z*(t) of blood from the electrical impedance spectroscopy is utilized to elaborate the impedance performance of blood during thrombus formation process. Experimental results indicate that the impedance Z*(t) of blood has regular variations under the formation of thrombus, which could be divided into three stages. Modified Hanai equation is proposed to quantitatively expound the three stages of impedance Z*(t) variation. The amount of fibrin and thrombus clot is founded to be accounted for the impedance variation of blood, which confirms the feasibility and theoretical basis of the non-invasive and on-line thrombus bio-detection technology for patients with serious cardiovascular disease.
More Related Videos
08:06Author Spotlight: Optimizing Porous Substrate Electroporation Through Micro and Nanochannels for Enhanced Monitoring and Intermediate Stage Characterization
Published on: September 27, 2024
05:44Performing In Vivo and Ex Vivo Electrical Impedance Myography in Rodents
Published on: June 8, 2022
Related Concept Videos
Impedance Combination
Impedances and Admittance
Impedance is a measure of resistance to sinusoidal current flow in an AC circuit. Unlike their behavior in DC circuits, where inductors appear as short circuits and capacitors as open circuits, the behavior of these components in AC...
Series Impedances: Three-Phase Line
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
RLC Series Circuits: Impedance
Thus, the magnitude of the impedance is given by the following equation,