Single-Digit Nanometer Electron-Beam Lithography with an Aberration-Corrected Scanning Transmission Electron Microscope
Published on: September 14, 2018
High contrast at low dose using a single, defocussed transmission electron micrograph
L Clark1, T C Petersen1, T Williams2
1School of Physics and Astronomy, Monash University, Victoria 3800, Australia.
Abstract:
For many soft-matter specimens, transmission electron microscopists face the double-bind of low contrast images, due to weakly-scattering specimens, alongside severe limits on the electron dose that can be used before the specimen is damaged by the electron beam. The combination of these effects causes the resultant micrographs to have very low signal-to-noise. It is well known that varying the defocus aberration can enhance image contrast in electron microscopy. For single-material objects where the variation of absorption and phase contrast are functions of one another, since both are governed by the variation in thickness profile, we show that the thickness profile can be reconstructed at very low dose. The algorithm, first established in X-ray imaging, requires some a priori information but only a single defocussed image of the region of interest, making it more dose efficient than either a conventional transport-of-intensity phase reconstruction (which would require two images and tends to amplify noise), or an absorption-contrast analysis of a single in-focus image recorded at the same electron dose (which does not benefit from the significant signal-to-noise enhancement of the present algorithm). These findings are presented through both simulations and experimental data.
Related Concept Videos
Transmission Electron Microscopy
Bioavailability Study Design: Single Versus Multiple Dose Studies
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Dose Size and Dosing Frequency: Determination Methods
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses