Background/Aim:
The parotid glands in the head and neck are organs at risks (OARs) adjacent to high dose region and dose of OARs might be increased during the course of radiotherapy. The influence factors of the dose distribution for the parotid glands were investigated in terms of weight loss and mandibular rotation for head and neck cancers treated with volumetric modulated arc therapy (VMAT).
Patients And Methods:
Ten oropharyngeal cancer patients (OPC) who underwent VMAT were enrolled. The dose volume histogram (DVH) parameters of the parotid glands and planning target volume (PTV) were compared between the planning computed tomography (CT) and the on board imager (OBI) at 1, 5, 10, 15, and 20 fractions.
Results:
The variation of dose distribution in PTV was not observed in both factors. The relationship between the mandibular rotation and dose difference for the right and left parotid glands (linear regression, r2=0.1577 and -0.689) showed a slighty stronger correlation with dose difference than the weight loss (linear regression, r2=-0.079 and -0.547).
Conclusion:
The mandibular rotation tends to have a large influence on dose distribution of the parotid glands for head and neck cancers treated with VMAT.
More Related Videos
05:18Author Spotlight: Improving Radiation Therapy Access with Radiation Planning Assistant
Published on: October 6, 2023
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Variation: Normal Distribution, Range, and Standard Deviation
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Variation
When independent and dependent variables are plotted on a scatter plot, the slope of a line is a value that describes the rate of change between the two...
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
Conservative Site-specific Recombination and Phase Variation
The recognition sites for Cre recombinase called LoxP...