Application of transcranial magnetic stimulation for major depression: Coil design and neuroanatomical variability
Samuel Zibman1, Gaby S Pell1, Noam Barnea-Ygael1
1Department of Life Sciences and the Zlotowski Centre for Neuroscience, Ben-Gurion University of the Negev, Beer-Sheva, Israel.
Abstract:
High-frequency repeated transcranial magnetic stimulation (rTMS) as a treatment for major depressive disorder (MDD) has received FDA clearance for both the figure-of-8 coil (figure-8 coil) and the H1 coil. The FDA-cleared MDD protocols for both coils include high frequency (10-18 Hz) stimulation targeting the dorsolateral prefrontal cortex (dlPFC) at an intensity that is 120% of the right-hand resting motor threshold. Despite these similar parameters, the two coils generate distinct electrical fields (e-fields) which result in differences in the cortical stimulation they produce. Due to the differences in coil designs, the H1 coil induces a stimulation e-field that is broader and deeper than the one induced by the figure-8 coil. In this paper we review theoretical and clinical implications of these differences between the two coils and compare evidence of their safety and efficacy in treating MDD. We present the design principles of the coils, the challenges of identifying, finding, and stimulating the optimal brain target of each individual (both from functional and connectivity perspectives), and the possible implication of stimulating outside that target. There is only one study that performed a direct comparison between clinical effectiveness of the two coils, using the standard FDA-approved protocols in MDD patients. This study indicated clinical superiority of the H1 coil but did not measure long-term effects. Post-marketing data suggest that both coils have a similar safety profile in clinical practice, whereas effect size comparisons of the two respective FDA pivotal trials suggests that the H1 coil may have an advantage in efficacy. We conclude that further head-to-head experiments are needed, especially ones that will compare long-term effects and usage of similar temporal stimulation parameters and similar number of pulses.
More Related Videos
Related Concept Videos
Design Consideration
The factor of safety is another key...
Transmission Line Design Considerations
Long-term Depression
Factorial Design
Design Example: Application of Archimedes' Principle
The volume of seawater displaced by the block is determined by first calculating the block's weight. This is done by multiplying the...
Group Design