A comparison of airway management devices in simulated entrapment-trauma: a prospective manikin study
Robin Pap1, Charl van Loggerenberg2,3
1School of Science and Health, Western Sydney University, Locked Bag 1797, Penrith, Sydney, NSW, 2751, Australia. r.pap@westernsydney.edu.au.
Introduction:
In the patient entrapped after a motor vehicle collision (MVC), advanced airway management may need to be performed before extrication. The aim of this study was to compare four airway management devices utilized by paramedics in a simulated entrapped patient.
Methods:
Twenty-six paramedics performed advanced airway management on a manikin seated in the driver's seat (right side) of a car. Access was through the opened door only. The airway devices were the Macintosh laryngoscope and the Airtraq optical laryngoscope to facilitate the endotracheal intubation (ETI), the laryngeal mask airway (LMA) Supreme and the laryngeal tube (LT). Time to first successful ventilation and number of attempts required for successful placement were measured. Following each placement, participants rated the degree of difficulty. For ETI, participants ranked the achieved glottic view using Cormack-Lehane grades (CLG). Finally, participants were asked which airway management device they preferred.
Results:
The LMA Supreme had the shortest mean time to first successful ventilation (16.7 s, CI [0.95] 14.9-18.6). Insertion of the LMA Supreme and ETI with the Macintosh laryngoscope had 100% first-attempt success. The LMA Supreme was rated least difficult to insert (mean score 1.7/10 (CI [0.95] 1.2-2.1)). Compared to the Macintosh, the Airtraq laryngoscope facilitated superior laryngoscopy (CLG I view 46.2% and 80.8%, respectively). Most participants (10/26; 38%) chose the Macintosh laryngoscope as their preferred technique, followed closely by the LMA Supreme (9/26; 35%).
Conclusion:
The LMA Supreme took the least amount of time and was the easiest to be inserted. Extraglottic airway devices may be beneficial alternative airway management devices to be considered by paramedics in the entrapped patient. Endotracheal intubation using the Macintosh laryngoscope was performed competently by participating paramedics. The Airtraq enabled superior laryngoscopy but resulted in poorer first-pass success rate.
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Appendicitis-II: Diagnostic Studies and Management
Diagnosing Appendicitis
It requires a multifaceted approach, starting with a detailed physical examination to pinpoint the location and nature of the pain and identify any associated symptoms. Laboratory tests play a crucial role. A complete Blood Count (CBC) typically reveals leukocytosis (an increased number of...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Acute Pyelonephritis II: Diagnostic Studies and Management
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...