Related Experiment Video
Updated: Jan 22, 2026

Controlling Parkinson's Disease With Adaptive Deep Brain Stimulation
Published on: July 16, 2014
Patient Experience with Rechargeable Implantable Pulse Generator Deep Brain Stimulation for Movement Disorders
Kyle T Mitchell1, Monica Volz2, Aaron Lee2
1Department of Neurology, University of California San Francisco, San Francisco, California, USA, kyle.mitchell@duke.edu.
Background/Aims:
Nonrechargeable deep brain stimulation implantable pulse generators (IPGs) for movement disorders require surgical replacement every few years due to battery depletion. Rechargeable IPGs reduce frequency of replacement surgeries and inherent risks of complications but require frequent recharging. Here, we evaluate patient experience with rechargeable IPGs and define predictive characteristics for higher satisfaction.
Methods:
We contacted all patients implanted with rechargeable IPGs at a single center in a survey-based study. We analyzed patient satisfaction with respect to age, diagnosis, target, charging duration, and body mass index. We tabulated hardware-related adverse events.
Results:
Dystonia patients had significantly higher satisfaction than Parkinson's disease patients in recharging, display, programmer, and training domains. Common positive responses were "fewer surgeries" and "small size." Common negative responses were "difficulty finding the right position to recharge" and "need to recharge every day." Hardware-related adverse events occurred in 21 of 59 participants.
Conclusion:
Patient experience with rechargeable IPGs was largely positive; however, frustrations with recharging and adverse events were common. Dystonia diagnosis was most predictive of high satisfaction across multiple categories, potentially related to expected long disease duration with need for numerous IPG replacements.
Related Concept Videos
Pulse
The pulse serves as a clinical...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Intrinsically Disordered Proteins
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
Anatomical Movements
Here are some common anatomical movements:
Flexion and extension motions are in the sagittal (anterior–posterior) plane of motion. These movements take place at the shoulder, hip, elbow, knee, wrist,...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...

