Related Experiment Video
Updated: Jan 22, 2026

18F-Labeling of Radiotracers Functionalized with a Silicon Fluoride Acceptor SiFA for Positron Emission Tomography
Published on: January 11, 2020
Temporal trends in test utilization and prevalence of ischaemia with positron emission tomography myocardial
Firas J Al Badarin1,2, Paul S Chan1,2, John A Spertus1,2
1School of Medicine, University of Missouri-Kansas City, 2411 Holmes St, Kansas City, MO 64108, USA.
Aims:
To examine whether test utilization and prevalence of ischemia with positron emission tomography (PET) myocardial perfusion imaging (MPI) follow the previously described trends with single photon computed tomography (SPECT).
Methods And Results:
MPI studies performed between January 2003 and December 2017 were identified. Number of PET and SPECT MPI studies performed per year was determined. Trends in the proportion of studies showing any ischaemia (>0%) with both modalities were compared before and after adjusting for baseline differences in patient characteristics using propensity scores. Interaction between imaging modality and year of testing was examined using modified Poisson regression. A total of 156 244 MPI studies were performed (30% PET and 70% SPECT). Between 2003 and 2017, the number of PET studies increased from 18 to 61 studies/1000 patient encounters, while SPECT volumes declined from 169 to 34/1000 patient encounters (P < 0.001 for within-group comparisons). The prevalence of any ischaemia in SPECT-tested patients declined from 53.9% to 28.3% between 2003 and 2017, whereas ischaemia prevalence in PET-tested patients declined from 57.2% to 38.2% (P < 0.001 for within-modality comparisons), with more PET studies showing ischaemia compared to SPECT [relative risk (RR) 1.44, 95% confidence interval (CI) 1.42-1.47; P < 0.001]. After propensity score matching of 26 066 patients tested with SPECT with 26 066 patients tested with PET, the between-modality difference in ischaemia prevalence was significantly attenuated, with a slightly higher overall likelihood of detecting ischaemia with PET compared to SPECT (RR 1.08, 95% CI 1.05-1.11; P < 0.001).
Conclusions:
Utilization of PET MPI at a large-volume referral centre increased significantly between 2003 and 2017. Despite a significant decrease in the prevalence of ischaemia with SPECT and PET during the same period, the decline was less with PET, perhaps related to baseline risk of tested patients.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Prevalence and Incidence
Prevalence indicates the proportion of individuals in a population who have a specific disease or health...
Emission Spectra
Current Trends in Nursing I
Current Trends in Nursing II

