Related Experiment Video
Updated: Jan 22, 2026

Isolation of Adult Spinal Cord Nuclei for Massively Parallel Single-nucleus RNA Sequencing
Published on: October 12, 2018
Adjacent level fracture incidence in single fraction high dose spinal radiosurgery
Dennis T Lockney1, Benjamin Hopkins2, Natalie A Lockney3
1Department of Neurosurgery, University of Florida, Gainesville, FL, USA.
Background:
Vertebral body compression fracture (VCF) is a complication following spinal stereotactic radiosurgery (SRS). However, the incidence of VCF in vertebrae adjacent to the level of SRS is unknown. This study aimed to determine the incidence of adjacent level VCF (adjVCF) following spinal SRS.
Methods:
A retrospective review of 239 lesions treated with single-fraction SRS from 2011-2014 was performed. Clinical and pathologic factors were collected including evaluation of VCFs in adjacent levels to SRS site. In patients with adjVCFs, dose-volume histograms for adjacent-level endplates were calculated. Cox regression analysis was performed to determine any association among clinical factors and adjVCF occurrence.
Results:
Median follow-up was 14.7 months. Twenty-six adjVCFs occurred (10.8%). Of the adjVCFs, 19 had metastases following SRS, and seven did not (2.9% of total treatments). Median time to fracture post-SRS was 13.5 months. In adjVCFs, median of the mean dose to adjacent level fractured endplate was 23.3 Gy, and median of the mean dose of sixteen non-fractured endplates immediately adjacent to the SRS site was 19.1 Gy. Age, gender, and histology were not associated with adjVCF.
Conclusions:
AdjVCF after spinal SRS occurs at a rate of 2.9%, when excluding metastatic sites of disease. Adjacent level endplates should be investigated as an organ at risk during SRS planning.
Related Concept Videos
Prevalence and Incidence
Prevalence indicates the proportion of individuals in a population who have a specific disease or health...
Bioavailability Study Design: Single Versus Multiple Dose Studies
Types of Reports II: Incident or Occurrence Report
Purposes:
In the healthcare industry, reports play a crucial role in documenting incidents within an agency. The primary objective of these reports is to ensure patient safety, uphold the...
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...

