Related Experiment Video
Updated: Jan 22, 2026

Magnetic Resonance Derived Myocardial Strain Assessment Using Feature Tracking
Published on: February 12, 2011
Inter-vendor reproducibility and accuracy of segmental left ventricular strain measurements using CMR feature
Monica Dobrovie1,2, Manuel Barreiro-Pérez3,4, Davide Curione3,5
1Department of Imaging and Pathology, University Hospitals Leuven, KU Leuven - University of Leuven, Herestraat 49, 3000, Leuven, Belgium. monica_dobrovie@yahoo.com.
Objectives:
Our aim was to evaluate the inter-vendor reproducibility of cardiovascular MR feature tracking (CMR-FT) for the measurement of segmental strain (SS) of the left ventricle (LV) as well as to test the accuracy of CMR-FT to detect regional myocardial pathology.
Methods:
We selected 45 patients: 15 with normal CMR findings, 15 with dilated cardiomyopathy, and 15 with acute myocardial infarction. Segmental longitudinal, circumferential, and radial strains were assessed with 4 different software. The inter-vendor difference as well as intra- and inter-observer variability was investigated. Furthermore, the accuracy of CMR-FT for the detection of structural (infarcted segments) as well as functional pathology (septal vs. lateral wall strain in left bundle branch block) was tested.
Results:
Between vendors, there were significant differences in values for all strains (p < 0.001). The software using a non-rigid algorithm for image registration and segmentation demonstrated the best intra- as well as inter-observer variability with interclass correlation coefficient (ICC) > 0.962 and coefficient of variation (CV) < 24%. For infarct location, the same software yielded the highest area under the curve values for radial and circumferential SS (0.872 and 0.859, respectively). One of the other three software using optical flow technology performed best for longitudinal SS (0.799) and showed the largest differences in SS between septum and lateral wall in the dilated cardiomyopathy group.
Conclusion:
SS values obtained by CMR-FT are not interchangeable between vendors, and intra- and inter-observer reproducibility shows substantial variability among vendors. Overall, the different packages score relatively well to depict focal structural or functional LV pathology.
Key Points:
• Segmental myocardial strain values obtained by CMR feature tracking are not interchangeable between different vendors. • Intra- and inter-observer reproducibility shows substantial variability among vendors. • Segmental myocardial strains measured by CMR feature tracking score relatively well to depict focal structural or functional LV pathology.
More Related Videos
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
09:05Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
Related Concept Videos
Uncertainty in Measurement: Accuracy and Precision
Measurements of Strain
Improving Translational Accuracy
Improving Translational Accuracy
Accuracy and Precision
Accuracy, limits, and approximation
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...