Related Experiment Video
Updated: Jan 22, 2026

Analyzing Neural Activity and Connectivity Using Intracranial EEG Data with SPM Software
Published on: October 30, 2018
The intracranial correlate of the 14&6/sec positive spikes normal scalp EEG variant
Vasileios Kokkinos1, Naoir Zaher2, Arun Antony2
1Department of Neurological Surgery, University of Pittsburgh, Pittsburgh, PA, USA; University of Pittsburgh Comprehensive Epilepsy Center, Pittsburgh, PA, USA.
Objective:
To investigate the intracranial correlate of the 14&6/sec positive spikes normal variant of scalp EEG.
Methods:
Out of 35 adult refractory focal epilepsy patients who underwent intracranial electrode implantation with simultaneous scalp EEG electrodes, the 14&6/sec positive spikes variant was found in 4. We used three methods to identify and quantify intracranial correlates to the variant: visual inspection, time-referenced waveform averaging and 3D brain volume spectrum-based statistical parametric mapping (SPM).
Results:
We discovered a novel and robust relationship between the scalp variant and an atypical hippocampal discharge. This intracranial correlate is an ipsilateral hippocampal burst of highly synchronized high-amplitude paroxysmal-like spikes of negative polarity, with a ramping up amplitude profile, which often ramps down and is accompanied by an underlying sequence of low-amplitude negative slow waves. The 14/sec positive spikes of the variant are time-locked to the negative peak of the hippocampal spikes, while the 6/sec positive spikes are time-locked to the negative spikes overlying the low-amplitude slow waves.
Conclusions:
The 14&6/sec positive spikes variant correlates with bursts of negative polarity spikes in the ipsilateral hippocampus.
Significance:
The identification of the hippocampal correlate of the 14&6/sec positive spikes variant fills a gap in our knowledge of normal intracranial variants. In clinical practice, this knowledge should reduce the chance that this electrophysiological signature is misinterpreted as epileptiform activity, which could inappropriately influence the interpretation of the intracranial study and subsequent surgical recommendation.
More Related Videos
06:19Visual Evoked Potential Recordings in Mice Using a Dry Non-invasive Multi-channel Scalp EEG Sensor
Published on: January 12, 2018
11:25Simultaneous Scalp Electroencephalography EEG, Electromyography EMG, and Whole-body Segmental Inertial Recording for Multi-modal Neural Decoding
Published on: July 26, 2013
Related Concept Videos
Correlations
Correlation and Causation
Correlation versus Causation
If the dependent variable increases or decreases when the independent variable increases, there is a positive or negative...
Histone Variants at the Centromere
Correlation
Two variables, for example, a and b, are said to be positively correlated if both variables move in the same direction. In other words, a positive correlation exists between two variables, a and b, if:
Normal Stress
When a rod is under axial loading, the internal forces and corresponding stress are normal to the plane of the section, so it is termed normal stress. It's important to...
Normal Distribution