Related Experiment Video
Updated: Jan 22, 2026

Objective Nociceptive Assessment in Ventilated ICU Patients: A Feasibility Study Using Pupillometry and the Nociceptive Flexion Reflex
Published on: July 4, 2018
Verifying the Japanese version of the Preschool Confusion Assessment Method for the ICU (psCAM-ICU)
Yujiro Matsuishi1,2, Haruhiko Hoshino1,2, Nobutake Shimojo1
1Department of Emergency and Critical Care Medicine Faculty of Medicine University of Tsukuba Tsukuba Ibaraki Japan.
Insights
This study validated the Japanese version of the Pediatric Confusion Assessment Method for the Intensive Care Unit (psCAM-ICU) for diagnosing pediatric delirium. The Japanese psCAM-ICU demonstrated high sensitivity, specificity, and reliability in pediatric intensive care settings.
Area of Science:
- Pediatric Intensive Care Medicine
- Neuroscience
- Psychiatry
Background:
- Pediatric delirium is prevalent (20-44%) in pediatric intensive care units (PICUs).
- Validated delirium assessment tools like the psCAM-ICU exist in English.
- No validated Japanese tools are available for pediatric delirium assessment.
Purpose of the Study:
- To verify the Japanese translation of the Preschool Confusion Assessment Method for the Intensive Care Unit (psCAM-ICU).
- To assess the validity and reliability of the Japanese psCAM-ICU in a Japanese pediatric intensive care setting.
Main Methods:
- Patients aged 6 months to 5 years in a Japanese PICU were assessed (May 2017-Feb 2019).
- Delirium was evaluated by three medical workers and verified against DSM-5 criteria by psychiatrists.
- Criterion validity (sensitivity, specificity) and reliability (Cohen's κ) were assessed.
Main Results:
- 56 assessments were conducted on 19 pediatric patients.
- The positive delirium rate was 54%.
- The Japanese psCAM-ICU demonstrated high sensitivity (0.90) and specificity (0.93), with excellent reliability (κ=0.92).
Conclusions:
- The Japanese translation of the psCAM-ICU is a valid and reliable tool.
- This tool can aid in diagnosing pediatric delirium in Japanese-speaking PICU settings.
- Facilitates improved delirium detection and management in Japanese pediatric patients.
Aim:
Pediatric delirium has been well investigated and its prevalence is reported to be from 20% to 44%. For pediatric intensive care settings, several validated assessment tools for diagnosing delirium, including the Preschool Confusion Assessment Method for the Intensive Care Unit (psCAM-ICU), are available in English. However, validated assessment tools for identifying pediatric delirium are unavailable in Japanese. Therefore, the aim of this study is to verify the Japanese translation of the psCAM-ICU.
Methods:
We enrolled patients at the Pediatric ICU at University of Tsukuba Hospital (Tsukuba, Japan) from May 2017 to February 2019. Enrollment criteria included patients aged 6 months to 5 years, and we excluded coma patients scoring under -4 on the Richmond Agitation-Sedation Scale or suffering from stroke. Pediatric patient delirium was simultaneously evaluated by three medical workers (pediatric intensivist and researchers). Psychiatrists then verified these findings against criteria of the Diagnostic and Statistical Manual of Mental Disorders - 5th Edition. We evaluated criterion validity (sensitivity and specificity) and reliability using Cohen's κ coefficient.
Results:
We made a total of 56 independent assessments of 19 patients (42% female) with an average age of 18 (±15) weeks. Mechanical ventilation was used at least once in 73% of patients and the positive rate of delirium was 54% in total observation. Overall, the psCAM-ICU showed high sensitivity, specificity (sensitivity, 0.90 [95% confidence interval [CI], 0.80-0.94]; specificity, 0.93 [95% CI, 0.83-0.97]), and high reliability within the researcher assessments (κ = 0.92; 95% CI, 0.82-1.0).
Conclusion:
We verified the psCAM-ICU and it shows high validity and reliability.
Related Concept Videos
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Assessment of the Mouth
Mouth Inspection
The inspection begins with visually examining the mouth for symmetry, color, and size.
The Scientific Method
The Scientific Method
Generally, predictions are tested using carefully-designed experiments. Based on the outcome of these...

