Related Experiment Video
Updated: Jan 22, 2026

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Bioaccumulation of Polycyclic Aromatic Hydrocarbons for Forensic Assessment Using Gas Chromatography-Mass
Marta Pastor-Belda1, Natalia Campillo1, Natalia Arroyo-Manzanares1
1Department of Analytical Chemistry, Faculty of Chemistry, Regional Campus of International Excellence "Campus Mare Nostrum" , University of Murcia , E-30100 Murcia , Spain.
Abstract:
Polycyclic aromatic hydrocarbons (PAHs) are considered xenobiotics of a potentially carcinogenic nature, being accumulated in the fatty tissue of the body. The objective of this work was the development and validation of a new analytical method to check the bioaccumulation of these toxic compounds in human organs obtained from autopsies. The contaminants were first isolated from the tissues by salt-assisted liquid-liquid extraction in acetonitrile. Because of the low concentrations of these compounds in the human body, a dispersive liquid-liquid microextraction procedure was included. The preconcentrated samples were analyzed by gas chromatography-mass spectrometry to identify the compounds. Principal component analysis was applied to show the natural clustering of forensic samples and orthogonal partial least-squares discriminant analysis to develop a multivariate regression method, which permitted the classification of samples. The quantification limits for the 13 PAHs (acenaphthylene, fluorene, phenanthrene, anthracene, pyrene, benzo(a)anthracene, chrysene, benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene, dibenz(a,h)anthracene, benzo(g,h,i)perylene, and indeno(1,2,3-cd)pyrene) analyzed were in the 0.06-0.44 ng g-1 range, depending on the compound, while the mean intraday relative standard deviation of about 7% demonstrated the high precision of the method. Linearity was verified in the 0.5-200 ng g-1 range, and the enrichment factors were between 55 and 122. The results provided by the analysis of seven different human organs (brain, liver, kidney, lung, heart, spleen, and abdominal fat) from eight autopsies confirmed the PAH-bioaccumulation capacity of human body, fat showing the highest degree of bioaccumulation. The present work is the first study on PAH contamination in different organs obtained from autopsies, being PAH detected in most human samples at values ranged from 0 to 19 ng g-1.
More Related Videos
04:39A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
09:09Semi-Quantitative Analysis of Peptidoglycan by Liquid Chromatography Mass Spectrometry and Bioinformatics
Published on: October 13, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Aromatic Compound Fragmentation
Aromatic Hydrocarbon Anions: Structural Overview
Due to the absence of continuous...
Aromatic Hydrocarbon Cations: Structural Overview
Removing one hydrogen from the intervening CH2 group...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...