Stress-engineered palladium nanowires for wide range (0.1%-3.9%) of H2 detection with high durability
Jae-Shin Lee1, Min-Ho Seo2, Kwang-Wook Choi1
1School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea. jbyoon@kaist.ac.kr.
Abstract:
Pd nanowire-based H2 sensors have attracted significant attention because of their superior sensing performance. However, when exposed to H2 concentrations of more than 2%, Pd experiences volume expansion over 10%, resulting in a significant amount of mechanical stress. Thus, exposure to such high H2 concentrations causes physical destruction of Pd nanowires, such as breaks and peel-offs, leading to severe difficulty in the reliable detection of H2 over a wide concentration range. Here, we proposed a structural approach to resolve this issue by introducing a partially anchored Pd nanowire (PA-PdNW) structure. In this configuration, most of the structure was air-suspended, leaving a small portion anchored to the substrate. Air-suspension enabled PA-PdNW to expand freely, thus relieving the mechanical stress; therefore, the Pd nanowires could withstand numerous exposures to high H2 concentrations. To demonstrate the PA-PdNW structure, we developed a nano-fabrication method based on conventional semiconductor processes and successfully manufactured H2 sensor devices with uniform, perfectly aligned PA-PdNW arrays stably air-suspended with designed gaps from the substrate. The fabricated sensors achieved reliable detection of H2 in the 0.1%-3.9% concentration range with a significant resistance change. In addition, compared with fully anchored Pd nanowire (FA-PdNW) sensors, the PA-PdNW sensors showed superior durability, and the nanowires retained their initial structures even after 300 exposures to high H2 concentrations. Furthermore, it was confirmed that the PA-PdNW sensor can stably operate even in extremely humid environments at 85% relative humidity.
Related Concept Videos
Circular Shaft - Stresses in Linear Range
Range
15.9; 16.1; 15.2; 14.8; 15.8; 15.9; 16.0; 15.5
Measurements of the amount of soda in a 16-ounce can vary since different subjects record these measurements or since the exact amount - 16 ounces of liquid, was not...
Brick Durability, Strength, and Appearance
¹H NMR: Long-Range Coupling
In alkenes, spin information is communicated via σ–π overlap, as seen in allylic (four-bond) and homoallylic (five-bond) couplings. These coupling interactions are stronger when the σ bond is parallel to the alkene...
What is Genetic Engineering?
Variation: Normal Distribution, Range, and Standard Deviation