Related Experiment Video
Updated: Jan 22, 2026

Computer-assisted Large-scale Visualization and Quantification of Pancreatic Islet Mass, Size Distribution and Architecture
Published on: March 4, 2011
Comparative accuracy of needle sizes and designs for EUS tissue sampling of solid pancreatic masses: a network
Antonio Facciorusso1, Sachin Wani2, Konstantinos Triantafyllou3
1Endoscopy Unit, University of Foggia, Foggia, Italy.
Background And Aims:
Variable diagnostic performance of sampling techniques during EUS-guided tissue acquisition of solid pancreatic masses based on needle type (FNA versus fine-needle biopsy [FNB]) and gauge (19-gauge vs 22-gauge vs 25-gauge) has been reported. We performed a systematic review with network meta-analysis to compare the diagnostic accuracy of EUS-guided techniques for sampling solid pancreatic masses.
Methods:
Through a systematic literature review to November 2018, we identified 27 randomized controlled trials (2711 patients) involving adults undergoing EUS-guided sampling of solid pancreatic masses that evaluated the diagnostic performance of FNA and FNB needles based on needle gauge. The primary outcome was diagnostic accuracy. Secondary outcomes were sample adequacy, histologic core procurement rate, and number of needle passes. We performed pairwise and network meta-analyses and appraised the quality of evidence using GRADE (Grading of Recommendations Assessment, Development and Evaluation) methodology.
Results:
In the network meta-analysis, no specific EUS-guided tissue sampling technique was superior, based on needle type (FNA vs FNB) or gauge (19-gauge vs 22-gauge vs 25-gauge) (low-quality evidence). Specifically, there was no difference between 25-gauge FNA versus 22-gauge FNA (relative risk [RR], 1.03; 95% confidence interval [CI], 0.91-1.17) and 22-gauge FNB versus 22-gauge FNA (RR, 1.03; 95% CI, 0.89-1.18) needles for diagnostic accuracy, sample adequacy, and histologic core procurement. Findings were confirmed in sensitivity analysis restricted to studies with no rapid on-site cytologic evaluation and no use of the fanning technique.
Conclusion:
In a network meta-analysis, no specific EUS-guided tissue sampling technique was superior with regard to diagnostic accuracy, sample adequacy, or histologic procurement rate for solid pancreatic masses, with low confidence in estimates.
Related Concept Videos
Network Covalent Solids
To break or to melt a covalent network solid, covalent bonds must be broken. Because covalent bonds are relatively strong, covalent network solids are typically...
Improving Translational Accuracy
Sample Size Calculation
The sample size for the given experiment or sampling effort is fundamental to any study design. Sample size decides the number of...
Uncertainty in Measurement: Accuracy and Precision
One-Way ANOVA: Equal Sample Sizes
Different sample means can result in different values for the variance estimate: variance between samples. This is because the variance between samples is calculated as the product of the sample size and the variance between the...
Comparing the Survival Analysis of Two or More Groups

