Related Experiment Video
Updated: Jan 22, 2026

Brachial Artery Catheterization in Swine
Published on: March 30, 2019
Radial Artery Catheterization for Neuroendovascular Procedures
Omaditya Khanna1, Ahmad Sweid1, Nikolaos Mouchtouris1
1From the Department of Neurological Surgery, Thomas Jefferson University Hospital, PA.
Transradial access for neuroendovascular procedures is safe and effective, with low complication rates and high patient satisfaction. Patients prefer this approach over transfemoral access due to shorter recovery times.
Area of Science:
- Neurology
- Vascular Surgery
- Interventional Radiology
Background:
- Radial artery catheterization is an emerging access route for neuroendovascular procedures.
- Limited studies exist on the safety and efficacy of this approach.
Purpose of the Study:
- To evaluate the safety and efficacy of transradial neuroendovascular interventions.
- To compare outcomes and patient satisfaction with transfemoral access.
Main Methods:
- Retrospective analysis of 233 neuroendovascular interventions using radial artery access.
- Comparison of outcomes in 98 patients who underwent both transradial and transfemoral procedures.
Main Results:
- Low overall complication rate (4.3% conversion to femoral access).
- Shorter procedure times for diagnostic angiograms (18.8 vs 39.5 minutes).
- High patient preference (94%) for transradial access due to shorter recovery.
Conclusions:
- Transradial catheterization is a safe and effective alternative for neuroendovascular procedures.
- The transradial approach offers advantages in procedure time and patient recovery.
- Patient preference strongly favors the transradial route over transfemoral access.
More Related Videos
09:23Shunt Surgery, Right Heart Catheterization, and Vascular Morphometry in a Rat Model for Flow-induced Pulmonary Arterial Hypertension
Published on: February 11, 2017
13:26Basic Surgical Techniques in the Göttingen Minipig: Intubation, Bladder Catheterization, Femoral Vessel Catheterization, and Transcardial Perfusion
Published on: June 26, 2011
Related Concept Videos
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization III: Left Heart Catheterization
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation