Related Experiment Video
Updated: Jan 22, 2026

Preparing Lamellae from Vitreous Biological Samples Using a Dual-Beam Scanning Electron Microscope for Cryo-Electron Tomography
Published on: August 5, 2021
Comparison of microcomputed tomography, cone beam tomography, stereomicroscopy, and scanning electron microscopy
İsmail D Çapar1, Tuba Gök2, Banu Uysal3
1Private Practice, Periodent Dental Clinic, İstanbul, Turkey.
Abstract:
The aim of the study was to compare different imaging methods in the diagnosis of microcracks on root dentin and to evaluate the frequency of dentinal microcracks observed after root canal preparation using the ProTaper Universal (PTU) system of different sizes. A total of 30 mandibular molars' mesial roots were scanned with microcomputed tomography (micro-CT) and cone beam computed tomography (CBCT) imaging methods before instrumentation. Root canal instrumentation was performed up to PTU F2 and F4 files. After instrumentation stages, the roots were scanned again with micro-CT and then with CBCT in same parameters. All roots were sectioned horizontally at 2, 4, 6, 8, and 10 mm from the apices of the specimens. The sections were imaged under a stereomicroscope. Finally, imaging of the sections was done by scanning electron microscopy (SEM). Statistical data analysis of instrumentation steps was performed using Friedman and Wilcoxon tests, and the data of imaging methods were analyzed using Kruskal-Wallis and Mann-Whitney U tests (p = .05). Instrumentation with the PTU system up to F2 and F4 files significantly increased the number of microcracks compared with preoperative samples according to micro-CT imaging (p < .05). For detecting microcracks on the root dentin, there were no statistically significant differences between micro-CT (43.9%) and stereomicroscopy (45.8%) (p < .05). SEM showed significantly higher percentage of microcracks (88.3%) (p > .05). No microcrack was observed using the CBCT method. There were no statistically differences between micro-CT and stereomicroscopy. SEM showed more dentinal microcracks while no microcrack was observed with CBCT.
More Related Videos
Related Concept Videos
Microcracking in Concrete
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Precipitate Formation and Particle Size Control
The obtained precipitate should be either a pure substance of known composition or easily converted to one by a simple process, such as ignition or drying. In addition, the precipitate should be insoluble and easily filterable. In general, filterability...

