AI-Assisted In Situ Detection of Human Glioma Infiltration Using a Novel Computational Method for Optical Coherence

Ronald M Juarez-Chambi1, Carmen Kut2, Jose J Rico-Jimenez1

  • 1Department of Biomedical Engineering, Texas A&M University, College Station, Texas.

Summary

A new AI-assisted optical coherence tomography method accurately detects glioma infiltration in brain tissue in real-time. This advances surgical tools for maximal tumor resection and improved patient outcomes.

Related Concept Videos

Computed Tomography01:10

Computed Tomography

Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
8.1K
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
295
Area Computation by the Alternative Coordinate Method01:24

Area Computation by the Alternative Coordinate Method

The alternative coordinate method, also known as the Shoelace Formula, is a technique for determining the area of a traverse using Cartesian coordinates. This method relies on the sequential arrangement of x and y coordinates for each point of the shape, ensuring accuracy and ease of application.In this approach, each corner's x and y coordinates are listed as fractions, with the x-coordinate as the numerator and the y-coordinate as the denominator. These coordinates are arranged sequentially...
571
Methods for Studying Drug Absorption: In situ01:09

Methods for Studying Drug Absorption: In situ

In situ experiments, such as the Doluisio method and Single-Pass Perfusion technique, provide critical insights into drug uptake by simulating in vivo conditions for drug absorption.
The Doluisio method involves perfusing a prepared segment of a rat's small intestine with a solution of radiolabeled drug and a non-absorbable marker. This helps to differentiate between absorbed and non-absorbed drug concentrations. The intestinal segment is connected at both ends using tubing and syringes,...
646
Effects of EDTA on End-Point Detection Methods01:18

Effects of EDTA on End-Point Detection Methods

Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
627
Precipitation Titration: Endpoint Detection Methods01:19

Precipitation Titration: Endpoint Detection Methods

In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
5.8K