Abstract:
Small-angle X-ray scattering (SAXS) is increasingly used to extract structural information from a multitude of soft-matter and biological systems in aqueous solution, including polymers, detergents, lipids, colloids, proteins and RNA/DNA. When SAXS data are recorded at multiple contrasts, i.e. at different electron densities of the solvent, the internal electron-density profile of solubilized molecular systems can be probed. However, contrast-variation SAXS has been limited by the range of electron densities available by conventional agents such as sugars, glycerol and salt, and by the fact that many soft-matter and biological systems are modified in their presence. Here we present a pioneering SAXS contrast-variation study on DDM (n-do-decyl-β-d-malto-pyran-oside) micelles by using two highly electron-rich contrast agents from biomedical imaging which belong to the families of gadolinium-based and iodinated molecules. The two agents, Gd-HPDO3A and iohexol, were allowed to attain modifications of the solvent electron density that are 50 to 100% higher than those obtained for sucrose, and are located between the electron densities of proteins and RNA/DNA. In the case of Gd-HPDO3A, an analysis of the internal micellar structure was possible and compared with results obtained with sucrose. In conclusion, medical contrast agents represent a promising class of molecules for SAXS contrast-variation experiments with potential appli-cations for numerous soft-matter and biological systems, including membrane proteins and protein-RNA/DNA complexes.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Conservative Site-specific Recombination and Phase Variation
The recognition sites for Cre recombinase called LoxP...
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Variation
When independent and dependent variables are plotted on a scatter plot, the slope of a line is a value that describes the rate of change between the two...
Variation of Atmospheric Pressure
Assuming the air temperature is constant at a given altitude and that the ideal gas law of thermodynamics describes the atmosphere to a good approximation, one can find the variation of atmospheric pressure with height.
Let p(y) be the atmospheric pressure at...
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...