Related Experiment Video
Updated: Jan 22, 2026

Retinal Vascular Reactivity as Assessed by Optical Coherence Tomography Angiography
Published on: March 26, 2020
Optical coherence tomography angiography image quality assessment at varying retinal expertise levels
Anne K Woetzel1, Jost L Lauermann1, Kiana Kreitz2
1Department of Ophthalmology, University of Muenster Medical Center, Muenster, Germany.
Purpose:
To compare optical coherence tomography angiography (OCT-A) image quality gradings performed by readers of varying retinal expertise levels in different retinal diseases.
Methods:
Central 3 × 3 mm2 OCT-A images (AngioVue, Optovue) of 57 healthy controls (50.9 ± 22.4 years) and 148 patients (66.5 ± 14.1 years) affected by various chorioretinal diseases were retrospectively analyzed including early age-related macular degeneration (AMD, n = 26), neovascular AMD (nAMD, n = 22), and geographic atrophy due to AMD (GA, n = 6), glaucoma (n = 28), central serous chorioretinopathy (CSC, n = 14), epiretinal membrane (EM, n = 26), retinitis pigmentosa (RP, n = 16), and retinal venous occlusion (RVO, n = 10). A senior expert in medical retina (SE), an ophthalmology resident (OR), and a non-ophthalmologic medical doctor (MD) independently assessed OCT-A image quality using the motion artifact score (MAS) and the segmentation accuracy score (SAS).
Results:
Regarding MAS, inter-reader agreement between SE and OR was 93.7% (Cohen's kappa = 0.907) and 85.4% (Cohen's kappa = 0.786) between SE and MD. Regarding SAS, inter-reader agreement between SE and OR was 95.1% (Cohen's kappa = 0.92) and 92.2% (Cohen's kappa = 0.874) between SE and MD. In the SAS analysis, signal strength index (SSI) and presence of retinal pathology had a significant influence on the overall agreement (P = 0.046; P < 0.001).
Conclusions:
OCT-A image quality assessment can be performed most reliably by an ophthalmologist with knowledge in retinal image analysis. Yet, well-instructed non-ophthalmologic assessors show only slightly inferior results and, thus, may be integrated in routine OCT-A image quality assessment as well.
Related Concept Videos
Gradually Varying Flow
Rapidly Varying Flow
Imaging Studies III: Computed Tomography
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
High-Level and Low-Level Awareness