Related Experiment Video
Updated: Jan 22, 2026

Author Spotlight: Advancements and Challenges in Surgical Treatments for Postamputation Pain
Published on: March 8, 2024
Randomized controlled clinical trial on calcium phosphate coated and conventional SLA surface implants: 1-year study
Kyung-A Ko1, Seungmin Kim1, Seong-Ho Choi1
1Department of Periodontology, Research Institute of Periodontal Regeneration, College of Dentistry, Yonsei University, Seoul, Republic of Korea.
Background:
Calcium phosphate (CaP)-coated surface showed enhanced contact osteogenesis around dental implant and finally accelerate osseointegration in early healing phase.
Purpose:
The aim of this randomized controlled trial was to compare the peri-implant marginal bone level around uncoated and CaP-coated sandblasted, large-grit, acid-etched (SLA) surface implants during the first year after placement.
Materials And Methods:
This study was performed upon 34 patients with randomized and double-blinded design. Clinical and radiographic examinations were performed immediately after implant placement, at re-entry after 3 months, and after 12 months to evaluate the initial stability and change in the marginal bone level. The distance from the implant shoulder to the top of the bone-to-implant contact was defined as the marginal bone level, and its alteration was measured at 1 year after implant installation.
Results:
None of the implants failed, and most of them showed a marginal bone loss of less than 1 mm. Small changes in the bone level were noted at all sites in the control and test groups, and there were no clinically significant differences in the changes in the marginal bone.
Conclusion:
Both CaP-coated and uncoated SLA surface implants showed comparably successful marginal bone stability without any complications during the first year after placement.
More Related Videos
Related Concept Videos
Clinical Trials
There are four phases in a clinical trial. A phase one...
Clinical Trials: Overview
Roles of Electrolytes: Calcium and Phosphate
The calcium concentration in blood plasma is primarily...
Statistical Software for Data Analysis and Clinical Trials
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
Reaction Rate
The mathematical representation of the change in the concentration of reactants and products, over time, is the rate...