Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy
Published on: May 8, 2018
Changes in Volume and Density Parameters Measured on Computed Tomography Images Following Stereotactic Body Radiation
Samuel Finkelstein1, Srinivas Raman1, Joanne Van Der Velden1,2
11 Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada.
Introduction:
Volumetric and density parameters measured from computed tomography scans were investigated for evaluating treatment response of nonspine bone lesions following stereotactic body radiation therapy.
Methods:
Twenty-three patients treated with stereotactic body radiation therapy to nonspine bone metastases with pre- and post-treatment radiological follow-up with computed tomography imaging were identified in a retrospective review. An expert radiologist classified 26 lesions by type (lytic, sclerotic) and by response. Two independent radiation oncologists created separate contours of the bone and soft tissue lesion volumes. Density and volume were assessed relative to baseline values.
Results:
For bone-only lesions, all lesions designated as local control decreased in volume or remained within 20% of baseline volumes. Lytic lesions classified as progressive disease exhibited much larger volume increases. Lytic bone lesions showed indications of remineralization with some exhibiting immediate increases in density (1-6 months) and others decreasing initially then increasing back toward baseline between 7 and 12 months. The majority of sclerotic lesions, all classified as local control, decreased slightly in both volume and density. Lesions with both soft tissue and boney involvement resulted in contradictory results when employing both radiological and size parameters for assessing treatment response. Classification was dominated by changes in soft tissue volume, despite associated volume or density changes in the corresponding boney lesion. In contrast, when soft tissue volume changes were minimal (<20% increase), classification appeared to be related primarily to density changes and not bone volume.
Conclusions:
Volume and density changes show promise as quantitative parameters for classifying treatment responses of nonspine osseous lesions. Further work is required for clarifying how these metrics can be applied to lesions with both boney and soft tissue components.
More Related Videos
08:17Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
Published on: June 7, 2015
12:23Multi-modal Imaging of Angiogenesis in a Nude Rat Model of Breast Cancer Bone Metastasis Using Magnetic Resonance Imaging, Volumetric Computed Tomography and Ultrasound
Published on: August 14, 2012
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Applications of the Ideal Gas Law: Molar Mass, Density, and Volume
Biological Effects of Radiation
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Radiation: Applications
The average...