Related Experiment Video
Updated: Jan 22, 2026

Randomized, Triple-Blind, and Parallel-Controlled Trial of Transcranial Direct Current Stimulation for Cognitive Rehabilitation after Stroke
Published on: June 6, 2025
Dexmedetomidine vs propofol as sedation for implantation of neurostimulators: A single-center single-blinded
Feline F J A Ter Bruggen1, Charlotte Ceuppens1, Leo Leliveld1
1Department of Anesthesiology, Center for Pain Medicine, Erasmus MC, Rotterdam, the Netherlands.
Background:
During the lead implantation of most spinal cord neurostimulators, the patient has to be comfortable and without pain. However, the patient is expected to provide feedback during electrical mapping. Titrating sedatives and analgesics for this double goal can be challenging. In comparison with our standard sedative agent propofol, the pharmacological profile of dexmedetomidine is more conducive to produce arousable sedation. The latter, however, is associated with hemodynamic side effects. We investigated whether dexmedetomidine is preferable over propofol during neurostimulator implantation.
Methods:
This single-center single-blinded randomized controlled trial included 72 patients with an indication for a neurostimulator, randomized to sedation with either propofol (0.5 mg/kg for 10 minutes, followed by 2.0 mg/kg/h) or dexmedetomidine (1 μg/kg for 10 minutes, followed by 0.6 μg/kg/h). The primary outcome was patient satisfaction with the sedation. The secondary outcomes were patient's and operator's comfort, number of titration adjustments, standard intraoperative hemodynamic and respiratory parameters and side effects.
Results:
Data of 69 patients (dexmedetomidine n = 35; propofol n = 34) were analyzed. Those receiving dexmedetomidine were more satisfied with the sedation than those receiving propofol; i.e. with sedation delivery (median 100.0 vs 83.3, P < .01), procedural recall (median 95.8 vs 83.3, P = .03), and sedation side effects (median 90.0 vs 83.3, P = .01). Fewer changes in the dexmedetomidine titration were necessary to maintain arousable sedation. Over time, mean arterial pressure and heart rate were significantly lower in the dexmedetomidine group. Hemodynamic side effects were comparable across groups.
Conclusions:
Dexmedetomidine sedation resulted in higher patient satisfaction and allowed for better arousable sedation than sedation with propofol. Although differences in hemodynamic parameters were found between the groups, these differences were not regarded as clinically relevant.
More Related Videos
Related Concept Videos
Blind Procedures
Brainstem: Control Centers of Medulla
Olivary Nucleus
The olivary nucleus, or inferior olivary nucleus, is located within the ventrolateral part of the medulla oblongata. It is primarily involved in motor coordination and motor learning. The olivary nucleus receives input from the spinal cord, cerebellum, and motor...
Blinding
Sedatives and Hypnotics: Overview
Sedative-hypnotics are categorized into barbiturates, benzodiazepines (BZDs), and non-benzodiazepines or Z-drugs. These drugs work by suppressing central nervous system activity, and this suppression is dose-dependent. Older sedative medications, like barbiturates, follow a linear curve in...
Load along a Single Axis
Consider a beam of length L subjected to a varying load, which is a combination of parabolic and trapezoidal load distribution along the x-axis. In this case, it is essential to determine the resultant loads, their locations, and...
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...

