Related Experiment Video
Updated: Jan 22, 2026

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
Published on: June 7, 2015
2D ultrasound imaging based intra-fraction respiratory motion tracking for abdominal radiation therapy using machine
Pu Huang1,2,3, Lin Su2,3, Shuyang Chen4
1Shandong Key Laboratory of Medical Physics and Image Processing, School of Physics and Electronics, Shandong Normal University, Jinan, Shandong, People's Republic of China.
Abstract:
We have previously developed a robotic ultrasound imaging system for motion monitoring in abdominal radiation therapy. Owing to the slow speed of ultrasound image processing, our previous system could only track abdominal motions under breath-hold. To overcome this limitation, a novel 2D-based image processing method for tracking intra-fraction respiratory motion is proposed. Fifty-seven different anatomical features acquired from 27 sets of 2D ultrasound sequences were used in this study. Three 2D ultrasound sequences were acquired with the robotic ultrasound system from three healthy volunteers. The remaining datasets were provided by the 2015 MICCAI Challenge on Liver Ultrasound Tracking. All datasets were preprocessed to extract the feature point, and a patient-specific motion pattern was extracted by principal component analysis and slow feature analysis (SFA). The tracking finds the most similar frame (or indexed frame) by a k-dimensional-tree-based nearest neighbor search for estimating the tracked object location. A template image was updated dynamically through the indexed frame to perform a fast template matching (TM) within a learned smaller search region on the incoming frame. The mean tracking error between manually annotated landmarks and the location extracted from the indexed training frame is 1.80 ± 1.42 mm. Adding a fast TM procedure within a small search region reduces the mean tracking error to 1.14 ± 1.16 mm. The tracking time per frame is 15 ms, which is well below the frame acquisition time. Furthermore, the anatomical reproducibility was measured by analyzing the location's anatomical landmark relative to the probe; the position-controlled probe has better reproducibility and yields a smaller mean error across all three volunteer cases, compared to the force-controlled probe (2.69 versus 11.20 mm in the superior-inferior direction and 1.19 versus 8.21 mm in the anterior-posterior direction). Our method reduces the processing time for tracking respiratory motion significantly, which can reduce the delivery uncertainty.
More Related Videos
Related Concept Videos
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Biological Effects of Radiation
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Respiratory Regulation of Acid-Base Balance
When carbon dioxide levels increase in the blood, more H+ and HCO3⁻ are...